Error mes-
Value
sage
Onboard
PROFINET
Transfer error
W#16#5007
PROFINET IO
Transfer error
W#16#5007
CM/PROFINET
IO
Program
W#16#5011
requires EF
lens
Save program W#16#500A
Match error
W#16#500B
Timeout
W#16#500D
during saving
TCP commu-
W#16#500E
nication
Archiving/
W#16#500E
MMI commu-
nication
Overload
W#16#500F
protection
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Value
Value
TCP/IP
Ident pro-
and
file
RS232
(STATUS)
07
E1FE04
07
E1FE04
17
E1FE06
10
E6FE04
11
E1FE07
13
E6FE04
14
E1FE01
14
E1FE01
15
E4FE06
10.1 Error and diagnostics messages
Description
The send buffer is full be-
cause the data cannot be
queried in an adequately
short time.
The send buffer is full be-
cause the data cannot be
queried in an adequately
short time.
An EF lens is configured in
the program but it is not
connected.
The program could not be
created.
The program could not be
created due to faulty match
settings.
The "Save program" process
was canceled because it took
too long.
Connection error in commu-
nication over a TCP connec-
tion or when using an
Ethernet RS-232 converter:
There is no TCP connection
or the data transfer cannot
be completed within the set
time limit.
Error in communication over
the archiving connection:
There is no TCP connection,
the server does not respond
within the set time limit or
violates the archiving proto-
col.
Processing mode was inter-
rupted to protect against
thermal or electrical over-
load.
The configured or specified
"Maximum duty cycle" under
"Settings > Options > Light-
ing" may have been exceed-
ed.
Service and maintenance
Corrective measures
Reduce the trigger frequency or
process the results faster. If nec-
essary, change the update time
in the PROFINET configuration.
Reduce the trigger frequency or
process the results more quickly
on the CPU. The transmission
speed of the communication
module connection can possibly
be increased.
To cover short-term peak loads,
the size of the image buffer in
the WBM can be increased un-
der"Program > Image acquisition
> Mode".
Reconnect the EF lens or change
the parameter assignment of the
program.
Adapt the parameter assign-
ment, the placement of test
objects in the image or the im-
age quality.
Adapt the match settings or use
a suitable test object.
Check the program settings and
start the "Save program" process
via the WBM, if necessary.
Make sure that the connected
TCP partner is correctly config-
ured and ready to receive.
Check the connection to the
server. Make sure that the data is
processed by the server in an
adequately short time and that
the protocol is maintained.
Switch off ring light elements,
reduce the trigger frequency,
reduce the exposure time or use
a more powerful ring light.
If the power supply is via PoE,
switch to an external power
supply via the combination inter-
face.
225