6. Maintenance and servicing
DANGER
Insufficient qualification
Inappropriate handling due to insufficient qualification can lead to serious property damage and
personal injuries or death.
•
Recommendation: Annually
Respective set of wear parts:
BEKOMAT
®
8
2000450
BEKOMAT
®
9
4005382
Before all maintenance:
•
Shut off the supply line
•
Press the TEST button until the BEKOMAT
•
Disconnect the BEKOMAT
6.1. Maintenance schedule
Maintenance
Functional test
•
Press the TEST button
•
Visual inspection
Maintenance
•
Replace the set of wear parts
•
Leakage test
•
Functional test
•
Check adhesive labels and replace if necessary
•
Check length of valve core
•
Check cable connections
•
Cleaning
Functional test:
The BEKOMAT
should be tested daily for flawless function.
®
•
To check the solenoid valve, press the TEST button briefly (approx. 2 sec.).
The BEKOMAT
starts manual drainage.
®
•
To check the fault signal, shut off the condensate inlet and press the TEST button for approx. 1 minute.
The BEKOMAT
starts manual drainage and triggers the alarm.
®
i
During this test, larger quantities of compressed gas can flow into the condensate collecting line.
Maintenance:
Further information about maintenance will be provided on request.
20
Maintenance work may only be carried out by trained service personnel from BEKO TECHNOLOGIES
GmbH or authorised partners.