3. Remove the pick roller.
Lift the right side of the bushing slightly (about 5 mm), move it toward the right, and then lift
it upward to pull out the pick roller.
ATTENTION
Be careful not to touch the grease on the gear near the bushing.
4. Attach a new pick roller to the ScanSnap.
Insert the left end of the shaft into the left-side hole, and then slowly attach the right end of
the shaft into place.
461