KitchenAid 1500299 Installation Instructions And Use & Care Manual page 30

2 burner outdoor gas grill
Table of Contents

Advertisement

Available languages

Available languages

5.
Reinsert the burner by sliding the middle tube of the gas
burner over the gas orifice and reattach using the cotter
clip previously removed. Repeat the procedure for each
main burner.
6.
Position the igniters so they are 3.18 mm (1/8") away from
each burner.
7.
Open the manual shutoff valve in the gas supply. The
valve is open when the handle is parallel to the gas pipe.
A.
B.
8.
Test all connections using an approved non-corrosive
leak-detection solution. Bubbles will show a leak. Correct
any leak found
Record Conversion
The LP appliance nameplate is located inside the grill cabinet
on the left-hand side. Once converted, place the NG appliance
nameplate over the current LP appliance nameplate.
In the last page of the Use and Care Guide, write "Converted to
Natural Gas". Also record the conversion date and the
technician/company that performed the conversion.
Closed valve
Open valve
Adjust High Flame Setting Screw
When converting from LP to Natural gas, you will need to
adjust the high flame setting screw for ideal burner flame
height.
1.
Remove each control knob for the main burners and sear
burner.
2.
Use a flat-blade screwdriver to turn the high flame
setscrew counterclockwise approximate 90º.
3.
Check that burner operates at the new high flame setting.
It may be necessary to adjust the screw setting slightly
more to get the ideal burner flame height.
4.
Place the burner control knobs back to their original
positions.
30