4.7 Disassembly/reassembly procedures of NX110
series
4.7.1 Panel Unit
The disassembly/reassembly procedures for NX100 series differ
C H E C K
from those of NX110 series, see
P O I N T
procedures.
Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire
(p
68)
Removal procedure
1.
Open the Scanner Unit.
Be careful when removing the Panel Unit, because the Main
C A U T I O N
Board and the Panel Board on the rear of the Panel Unit are
connected with the Panel FFC.
Be careful when carrying out the next procedure, because the
hook on the rear of the Panel Unit is fragile and easily gets
damaged or softened.
Make sure to work with both hands.
2.
Slide the Panel Unit back with lifting the rear side slightly. And remove the
Panel Unit.
Panel Unit
Middle Housing
Figure 4-116. Removing the Panel Unit (1)
DISASSEMBLY/ASSEMBLY
" 4.4.1 Panel Unit " ( p. 72 )
for the
Hook
Positioning Hole
Disassembly/reassembly procedures of NX110 series
When disconnecting the Panel FFC from the connector (J2) on the
C A U T I O N
Main Board, hold the Panel FFC and pull it directly above from
the connector (J2).
3.
Disconnect the Panel FFC from connector J2 on the Main Board, and remove
the Panel Unit.
Panel FFC
J2
Figure 4-117. Removing the Panel Unit (2)