The configuration mode is used to set the RAK148H2 to
match the heating/cooling system. This thermostat function
with up to 2-stage heat pump systems.
To configure the RAK148H2, perform the following steps:
Note: Operation being set will blink in the display.
1. Slide the Function switch to the OFF position.
2. Remove the thermostat's front cover.
3. To enter the configuration mode, simultaneously hold
the LEFT and RIGHT buttons in for 3 seconds while the
thermostat is in OFF mode. (See diagram on page 3.)
4. Once in the configuration mode, press the
button to change settings within each screen.
- Press the RIGHT button to advance to the next screen.
- Press the LEFT button to return to the previous screen.
NOTE: To exit configuration mode at any time, slide the
Function switch to Heat or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. Temperature Scale (°F or °C)—Choose
Fahrenheit or Celsius.
Press the
Press the RIGHT button to advance to the next screen.
NOTE: Default factory setting is Fahrenheit.
2. Heat System—Check model number on the Hotpoint
chassis to determine the primary heating method.
AZ11H***** is a heat pump and is the thermostat factory setting.
AZ11E***** is a straight electric heat model and requires a mode
setting change.
To change the heating mode configuration, press the
RIGHT button to advance to the HSH screen. Press the
or
Press the RIGHT button to advance to the next screen.
3. Temperature Differential—Stage 1—
(1–9°F) (1–5°C)
Set the number of degrees between the
"setpoint" temperature and the
"turn on" temperature for first stage.
10

CONFIGURATION MODE

or
button to select.
button to select HSE.
or