5.9

Connect the ground

Safety notes
Protection against explosion
For safety reasons, all shields should be connected at both ends when using shielded leads
and the associated production resources should be connected to the equipotential bonding
of the hazardous area. Use only approved intrinsically safe power sources, as described in
the "Technical Data" section.
The grounding connection of the item must be connected to the potential balance.
Procedure
In order to connect the ground, proceed as follows:
1. Guide the earth cable through the cable gland ⑦.
2. Connect the grounding cable to the grounding screw on the mounting plate.
SITRANS DA400 for material flow monitoring with protection against explosion
Operating Instructions, 09/2007, A5E00841152-01
WARNING
Connecting
5.9 Connect the ground