Disposal; Extension And Conversion; Troubleshooting - Bosch Rexroth IMenip2 Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

24/28
Bosch Rexroth AG
12

Disposal

Environmental protection
Careless disposal of the IMenip2 interface
module could lead to pollution of the environ-
ment.
Therefore dispose of the device in accord-
ance with the currently applicable regulations
in your country.
You can also send the device to Bosch
Rexroth for disposal.
13
Extension and conver-
sion
Do not convert the IMenip2 interface module.
IMenip2 | 3 608 870 F34/2017-05
14

Troubleshooting

Malfunctions and information on errors are
displayed in the tightening system, e.g. in the
BS350.
The NS LED indicates the Ethernet status.
Tab.4: NS
LED display
Meaning
Red
Double IP address or block-
ing error
Flashing red
Time-out reached in one or
more connections (CIP class
1 or 3)
The MS LED indicates the interface module
status.
Tab.5: MS
LED display
Meaning
Red
Error (exception error or blocking
error)
Flashing red
Self-acknowledged error. Used
configuration differs from stored
configuration
If you should not be able to remedy an occur-
ring defect, please contact one of the ad-
dresses that you can find under
www.boschrexroth.com or in the address di-
rectory in chapter "16 Service and sales" on
page 26.