7.4 Mounting of the cabinet feet

Unplanned drop of the unit
Risk of injury.
▶ Follow the safety precautions in 7.2: Lifting methods
▶ Use support to provent drop.
The cabinet feet (option) minimizes the vibrations and makes it easy to level
the Drive Unit. They are delivered separately within the cabinet and have to be
mounted according to the following instructions:
1. Mount the cabinet feet before filling hydraulic fluid in the tank.
2. Mount the cabinet feet before the electric motor(s), if they are delivered
separately or supplied by the customer.
3. Lift the Drive Unit according to 7.2: Lifting methods. Notice especially the safety
precautions.
4. Mount the cabinet feet according to Fig. 20 and Table 11. Level the Drive Unit by
the adjusting screws.
Adjustment
screw
Fig. 20: Adjusting cabinet feet
Table 11: Adjusting cabinet feet
Cabinet size
DUc MS2
DUc MT2, LS2, LT2, LS3,
LT3
Installation | Hägglunds DUc Drive unit
CAUTION
Adj. height
Adj. screw
A
head size
mm
in
mm
25-32
1-1.25
18
1.18-
30-38
24
1.50
RE 15326-WA, Version 06.2020, Bosch Rexroth AB
33/88
B
DD00072983
Hole Ø
B
in
mm
in
0.71
15
0.59
0.94
20
0,79