2 | AMC2 4W-EXT - Wiegand Extension Board
The AMC2 4W-EXT is connected to the AMC2 4W using the
RS-485 extension interface. This interface will also be used
to connect further extension modules.
Installation/Configuration Notes
The number of controllers in one system is limited to 200.
The using of AMC2 4W-EXT modules has no influence on this
limit, because it is an extension to an AMC2 4W and not a
controller.
Using Wiegand interfaces, up to eight peripheral devices
can be connected to each AMC2 4W. The interfaces are
point-to-point connections, meaning that only one reader
can be connected to one interface.
Power supply
An external power supply (10 to 30 V DC) for the AMC2 is
connected to the first (positive) and third pin (negative).
When using an uninterruptible power supply (UPS), the
relevant UPS output relay is connected to the pins
4 and 7 for alternating current (AC)
5 and 7 for the battery
6 and 7 for direct current (DC)
Otherwise, these pins will short-circuit.
Voltage equalization - grounding
Different grounds can be balanced via jumpers with
protective ground.
A line (shielding, potential equalization) with protective
ground must only be connected in one place.
For further instructions, please see the operating
manual.
Wiegand interface
The AMC2 4W-EXT has four interfaces to connect up to four
readers. The following definitions apply to the interface:
10 wire interface with shield
Max. cable length: 158 m (172.8 yd)
26 bit wiegand format
37 bit wiegand format
Default configuration:
1 = Reader Supply – 12V+
2 = Reader Supply – 0V
3 = Data 0
4 = Data 1
5 = Shield
6 = green LED
7 = red LED
8 = Beeper
9 = Hold
10 = Card Present
Contacts
Inputs
The analog inputs can be used as digital or analog contacts.
For analog use, resistance values can be specified to check
for cable breaks and short-circuits.
Relay outputs
The relay outputs offer the following functions:
The outputs can operate with potential free contacts for
external power supply (dry mode).
The outputs can operate using the internal voltage of
power supply (wet mode).
Only ohm resistive loads can be connected to the relay.
Inductive loads must be bypassed via recovery diodes.
These diodes (1N4004) are enclosed.
General instructions
All access equipment should be mounted within a
"secured area".
Detailed connection conditions are specified in the
operating manual!
After purchase, primary AC power must be carried out
by a licensed electrician.
Technical Specifications
Hardware
4 Wiegand reader interfaces
8 relay outputs - with ohm load:
- max. switching voltage: 30 V DC
- max. switching current: 1,25 A
8 analog inputs
Tamper switch
Temperature
0°C to +45°C (32° F to 113° F)
Power supply
- 10 or 30 V DC, max. 60 VA
Available for external devices: 55 VA
- or via the AMC2
Protection
IP 30
class
Housing
Base: PPO (UL 94 V-0)
Upper: Polycarbonate (UL 94 V-0)
Color
White
Dimensions
WxHxD: 232 x 90 x 46 mm (9.13 x 3.54 x 1.81 in.)
Weight
Approx. 0.4 kg (0.88 lb)
Type
Rail mounting