Download Print this page

Bosch Rexroth MSK Project Planning Manual page 63

Synchronous servomotors for potentially explosive areas

Advertisement

DOK-MOTOR*-MSK*EXGIIK3-PR09-EN-P
Synchronous Servomotors MSK For Potentially Explosive Areas
5.19
MSK071C-...-NSNN Technical data
Designation
Continuous torque at standstill 60 K
Continuous current at standstill 60 K
Maximum torque
Maximum current
Torque constant at 20 °C
Voltage constant at 20 °C
1)
Winding resistance at 20 °C
Winding inductance
Leakage capacitance of the compo‐
nent
Number of pole pairs
Moment of inertia of rotor
Thermal time constant
Maximum speed (electric)
Sound pressure level
Mass
2)
Ambient temperature during operation
Protection class (EN 60034‑5)
Thermal class (EN 60034‑1)
Symbol
Unit
MSK071C-0200-NN
M
Nm
0_60
I
A
0_60(eff)
M
Nm
max
I
A
max(eff)
K
Nm/A
M_N
V/1000
K
155.5
EMK_1000
min-1
R
Ohm
12
L
mH
12
C
nF
dis
p
-
J
kg*m
2
red
T
min
th
n
min
-1
max el
L
dB[A]
P
m
kg
T
°C
amb
-
-
T.CL.
-
1)
Manufacturing tolerance ±5%
2)
(...) Motors with holding brake 1, 2, ...
Tab. 5-47:
Technical data MSK017C-...-NSNN
Tab. 5-48:
Technical data MSK071C-0200-__-__-___-_S__
Bosch Rexroth AG
MSK071C-0300-NN
12.0
5.2
7.3
44.0
23.4
32.9
2.50
1.80
110.5
3.1
1.68
19.5
10.9
4.6
4
0.00173
28.0
3500
5000
Less than 75
13.9 (15.8)
0 ... 40
IP65
155
61/175
Technical data
MSK071C-0450-NN
8.9
40.1
1.49
91.3
1.1
6.7
4.2
5800
Last amended: 2014-01-21

Advertisement

loading