Parameter Lists

4.1.3 F-## Fundamental Parameters

Par. No. # Parameter description
F-0#
F-01
Frequency Setting 1
F-02
Operation Method
4
4
F-03
Max Output Frequency 1
F-04
Base Frequency
F-05
Motor Rated Voltage
F-07
Accel Time 1
F-08
Decel Time 1
F-09
Torque Boost
F-1#
F-10
Electronic Overload
F-11
Motor External Fan
F-12
Motor Thermistor Input
F-15
Motor Speed High Limit [Hz]
F-16
Motor Speed Low Limit [Hz]
F-17
Motor Speed High Limit [RPM]
F-18
Motor Speed Low Limit [RPM]
F-2#
F-20
PM Start Mode
F-22
Start Speed [RPM]
F-23
Start Speed [Hz]
F-24
Holding Time
F-25
Start Function
F-26
Motor Noise (Carrier Freq)
F-27
Motor Tone Random
F-28
Dead Time Compensation
F-29
Start Current
F-3#
F-33
Source for User-defined Readout
F-37
Adv. Switching Pattern
F-38
Overmodulation
F-4#
F-40
Torque Limiter (Driving)
F-41
Torque Limiter (Braking)
F-43
Current Limit
F-5#
F-50
Reference Range
F-51
Reference/Feedback Unit
F-52
Minimum Reference
F-53
Maximum Reference
F-54
Reference Function
F-6#
F-62
Catch up/slow Down Value
F-64
Preset Relative Reference
F-68
Relative Scaling Reference Resource
F-9#
F-90
Step Size
F-91
Accel/Decel Time
F-92
Power Restore
166
Default value
ExpressionLimit
All set-ups
[0] Linked to Hand / Auto
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] None
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Rotor Detection
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 s
All set-ups
[2] Coast/delay time
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[1] On
All set-ups
0 A
All set-ups
[240] Default Source
All set-ups
[1] SFAVM
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Sum
All set-ups
0 %
All set-ups
0 %
All set-ups
[0] No function
All set-ups
0.10 %
All set-ups
1 s
All set-ups
[0] Off
All set-ups
02/2016 All rights reserved.
4-set-up
Change
Conver-
during
sion index
operation
TRUE
TRUE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Type
-
Uint8
-
Uint8
-1
Uint16
0
Uint16
0
Uint16
-2
Uint32
-2
Uint32
0
Int16
-
Uint8
-
Uint8
-
Uint8
-1
Uint16
-1
Uint16
67
Uint16
67
Uint16
-
Uint8
67
Uint16
-1
Uint16
-1
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint32
-
Uint8
-
Uint8
-
Uint8
-1
Uint16
-1
Uint16
-1
Uint32
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-2
Int16
-2
Int32
-
Uint8
-2
Uint16
-2
Uint32
-
Uint8