16.4 Ambient conditions

• The ActiveShuttle is designed for mobile use in indoor areas.
• Operating temperature +5 °C to +40 °C
• Storage temperature
–20 °C to +45 °C
• Relative humidity
5 % to 85 %, non-condensing
• Degree of
3 according to IEC 61010:
contamination
• Air pressure:
> 84 kPa, corresponds to an altitude < 1400 m above
sea level
• At altitudes > 1400 m, the load values of the electric drives are reduced by 15 %.
• The area should be kept free of mold, fungus, rodents and other vermin.
• Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
• Do not install or operate near sources of sand or dust.
• Do not install or operate in areas that are regularly subjected to high-energy forces
caused, for example, by presses or heavy machinery.
• Contact with highly reactive acidic or alkaline substances must be avoided.

16.5 Floor requirements

• Slope/gradient: max. 2.5 % only in driving direction (forwards or backwards)
• Lateral inclination: not permitted
• Flatness: according to DIN 18202, table 3 line 3
• Strength: static 6 ... 8 N/mm²; dynamic 12 ... 16 N/mm
• Surface fi nish: 0.8 ≥ µ ≥ 0.6 (wheel material: Vulkollan)
• Electrical conductivity: R
• Joints: max. 6 mm high, max. 15 mm wide
3 842 560 593/2020-07 ActiveShuttle: ActiveShuttle 1.0, Bosch Rexroth AG
9
< 1 x 10
Ω (ESD applications)
g
Technical data
59/68