11.3.3 Setting Output Conditions

When "Output setting" is set to "Computer Link", the following Computer Link parameters are displayed.
Output Settings: Number of Scans, Judgment, Numeric Calculation, Statistics
Select output data of each item from the menu.
Selecting a PLC Model: Panasonic FP/MELSEC A+Q/MELSEC FX/OMRON C+CV+CS1/ AB SLC/ MICREX SX
Select a PLC Model to be used for Computer Link.
Start Register: Settable Range "0000 to 9999"
Specify the start register number to output data to the PLC.
First output data are stored in the register of the specified number.
Timeout (ms): Settable Range "20 to 20000 ms" (in 1 ms unit)
Set the limit time from PLC to Response after the data were output. if
PLC does not send any response within the time limit
"Time out error" will occur and the PV310 will output the error signal.
Data Type: 16 bit / 32 bit
Specify the bit length of output data. The data of the following bit length can be output:
16 bit: -32768 to +32767 (if output data is more than 16 bits, OVF (overflow) signal is output.)
32 bit: -2147483648 to +2147483647
But, Judgment results are output in digit unit regardless of Data Type setting.
Note that some of the register numbers from 0000 to 9999 are unavailable depending on the type of PLC.