Page 3
INDEX 1 DIAGNOSTICS on dryer EDR 1000 / EDR 2000 / EDR2000 JEWEL / EDR 2000 CLUB DISPLAY .... 5 1.1 Access to diagnostics ..........................5 1.2 Exiting the diagnostics system ........................ 5 2 Allarms ................................6 2.1 ALARMS EDR 1000 ..........................6 2.1.1 Displaying the alarms to the user .....................
Page 4
17 STEAMER ..............................39 18 List of PNC ..............................40 18.1 List of PNC - ELC for dryer EDR 1000 NEW ..................40 18.2 List of PNC - ELC for dryer EDR 2000 NEW ..................40 18.3 List of PNC - ELC for dryer EDR 2000 JEWEL................... 42 18.4 List of PNC - ELC for dryer EDR 2000 CLUB DISPLAY ..............
Page 5
1 DIAGNOSTICS on dryer EDR 1000 / EDR 2000 / EDR2000 JEWEL / EDR 2000 CLUB DISPLAY 1.1 Access to diagnostics EDR 1000 EDR 2000 EDR 2000 JEWEL EDR 2000 CLUB DISPLAY 1. The appliance must be switched OFF. 2. Press START/PAUSE and the option buttons simultaneously.
LED lights and the buzzer sounds. 2 Allarms 2.1 ALARMS EDR 1000 2.1.1 Displaying the alarms to the user Operation of the alarms is configurable according to the model. Some or all of the alarms may be displayed to the user.
2.1.2 Alarm display during normal operation The system displays the family of alarms to the user by a repeated flashing sequence of the ANTI-CREASE/END OF CYCLE LED (0.4 seconds on, 0.4 seconds off, with a 2.5 second pause between sequences). The buzzer emits a series of "bips"...
2.1.5 Example of display of alarm code In the event of, for example, alarm E53 (problems with the motor triac), the code will be displayed as follows: the sequence of five flashes of the ANTI-CREASE/END OF CYCLE LED indicates the first of the two numbers in the alarm code E"5"3, which represents the family and is displayed to the user.
Page 9
Configuration alarm E93: When configuration alarms are displayed (when the appliance is switched on), the appliance is inoperative and all the LEDs light. It is not possible to access diagnostics mode; the only possible operation is that of switching off the appliance (selector knob on position "0"). ...
Page 10
The alarm code is displayed by a repeated sequence of flashing of the ANTI-CREASE/END OF CYCLE LED (0.4 seconds on, 0.4 seconds off, with a pause of 2.5 seconds between sequences). The buzzer emits a series of "bips" in synchronization with the flashing of the LED. ...
Page 11
Alarms EB1-EB2-EB3: In the event of problems with the power supply, the appliance remains in alarm mode until the voltage and frequency are restored to within the normal limits or the appliance is switched off (selector knob on position "0"). Alarm family "B" is displayed and it is not possible to access diagnostics mode nor to use the "rapid alarm display"...
Page 12
The alarm code is displayed by a repeated sequence of flashing of the ANTI-CREASE/END OF CYCLE LED (0.4 seconds on, 0.4 seconds off, with a pause of 2.5 seconds between sequences). The buzzer emits a series of "bips" in synchronization with the flashing of the LED. ...
Page 13
Alarms EB1-EB2-EB3: In the event of problems with the power supply, the appliance remains in alarm mode until the voltage and frequency are restored to within the normal limits or the appliance is switched off (selector knob on position "0"). Alarm family "B" is displayed and it is not possible to access diagnostics mode nor to use the "rapid alarm display"...
2.4.4 Cancelling the last alarm It is good practise to cancel the alarm code from memory: • After reading the alarm, to check whether it comes up again during the diagnostic cycle. After carring out the repair, to check whether it comes up again during the test cycle.
Page 15
2.5 Table of alarms EDR 1000 / EDR 2000 / EDR2000 JEWEL / EDR 2000 CLUB DISPLAY Reset Alarm Description Possible fault Action/machine status command No alarm Canister fill pump triac faulty Wiring faulty. Electronic board faulty. Cycle interrupted Triac "sensing" circuit for the canister fill pump faulty Electronic board faulty.
Page 16
NTC sensor faulty. Wiring faulty. Electronic board NTC sensor faulty. Forced cooling cycle. faulty. Error in the communication between electronic Wiring faulty. Electronic board faulty. Cycle interrupted board and control/display board Control/display board faulty. SOI/ADL 2009-10 16/59 599 72 40-73 Reset Alarm Description...
3 DIAGNOSTICS ENV06 / ENV06 AEG / ENV06 CATALOGUE / ENV06 ACTION / ENV06 input 3.1 Acess to diagnostics 1. Press the defined combination key (START + the nearest key on the left) and keeping them pressed 2. Switch on the machine rotating the main selector in the 1st position CW.. In the ENV06 INPUT press the ON / OFF push button 3.
Page 19
Position 2 Condense Tank Switch and Purpose of test: To test the condense tank pump and switch Pump Activated components: If the pump is full of water and the tank switch recognises the condition, the pump is switched Until the condense switch is on full position, Behaviour: phase LEDs blink;...
Page 20
Position 7 ( Dryer with CONDUCTIMETRIC sensor ) Conductimetric sensor. To verify conductimetric sensor in short circuit Purpose of test: Drum short circuit condition. Activated components: Conductimetric sensor reading. Behaviour: The step lasts 4 seconds (software configured). During this time all phase LEDs blinks to give information of acquisition phase.
Page 21
Behaviour: Until the condense switch is on full position, phase LEDs blink. When the switch goes on void position the LEDs are switched OFF. Working conditions: Door closed. Position 10 ( Dryer with CONDUCTIMETRIC sensor ) Last alarm display and Purpose of test: To see the allarm and reset it possible reset...
Page 22
4 DIAGNOSTICS on ENV06 / ENV06 AEG CLOTHES REFRESHMENT 4.1 Acess to diagnostics 1. Press the defined combination key (START + the nearest key on the left) and keeping them pressed 2. Switch on the machine rotating the main selector in the 1st position CW.. 3.
Page 23
Behaviour If steamer tank switch is on void position, the related icon blinks on LCD, but this not prevents the steamer to be heated up. Position 3 Steamer Pump + To test the steamer pump and steamer in general Steamer Water/Steam Purpose of test: (pipes, connections, etc.).
Page 24
Position 7 Heater full power + To test the ½ & full power-heating element. Clockwise drum Purpose of test: rotation + Full Fan Both heating elements, Drum Motor and Main Fan Activated components: on direct direction to give ventilation full speed. Behaviour The digits on LCD show NTC1 drying temperature.
Page 25
If steamer tank switch is on void position, the related icon Behaviour blinks on LCD, but this not prevents the steamer to be heated up. The digits on LCD will show NTC2 steamer temperature. Phase LEDs are switched ON. Working conditions: Door closed (Time out 30 sec.) Position 12 Last alarm display and...
Page 26
5.2 Exiting the diagnostics system To exit from DIAGNOSTIC mode it’s sufficient to switch off the machine. According to the machine configuration, it’s possible that the next machine switch on, the electric test cycle will be activated. To stop it, switch off again the machine. Moving the main knob in clockwise direction, the following tests will be done: Position 1 User Interface Test...
Page 27
Behaviour: The digits on LCD show NTC1 drying temperature. Working conditions: Door closed (Time out 10 min.) Position 6 Clockwise drum To test motor in clockwise direction, circulation fan rotation + Main Fan + Purpose of test: motor TRIAC, the function of the main fan and the compressor compressor Activated components:...
Page 28
Position 10 Last alarm display and Purpose of test: To see the allarm and reset it possible reset Behaviour: The LCD displays the alarm while the LED will flash on the basis of alarm Working conditions: Turn the knob till position 10, paying attention not to stop to position 7, otherwise error 32 may occur 6 ALARMS ENV06 dryers...
Page 29
Displaying other alarm codes Pressing START button, all alarms in the appliance will be displayed. The configuration errors E93 are displayed through the flashing of all LEDs and it is not possible to access the diagnostics system. 6.6 Cancelling the last alarm memorized It is good practise to cancel the alarm code from memory: •...
Page 30
7 ENV06 TUMBLE DRYERS ALARMS TABLE SUMMARY Tank Pump Disconnected (Wiring or Connector Failure) Tank Pump Failure Stops cycle execution. Ex21 PUMP_TRIAC_AL Condense Pump Alarm Tank Pump Triac Failure (Short Circuit, Diode Mode, Open If detected on setup, does not allow cycle start. Circuit) (Main Board Failure) PUMP_TRIAC_S_AL Condense Pump Sensing...
Page 31
FCV Board - Motor Wiring Disables motor moving and shutdon FCV board for 2 mintues, then Motor Connector FCV is switched on and drum moving enbaled. Ex57 FCV_CURRENT_TRIP_AL FCV Current Trip Failure If this problem conitues after 5 retrials the cycle is stopped and ...
Page 32
Main Fan Motor Failure Disables main fan and heater/compressor for a while, waiting for Main Fan Motor Triac Failure (Short Circuit, Diode Mode, Main Fan Thermal cut-off possible thermal restoration. Ex66 MAIN_FAN_AUT_THERM If after 30 minutes (more or less) the situation does not return Alarm Open Circuit) (Satellite Board Failure) normal sets 0x66 alarm...
Page 33
Wiring Failure Disables cycle execution until the communication is not restored. CRM Satellite Board ExA1 Satellite Board Failure CRM_BOARD_COM_AL Communication Alarm Main Board Failure CRM Satellite Board CRM_BOARD_PROT_INCO Stops cycle execution. Software of Main Board and Satellite Board are not compatible ExA2 Protocol Incongruence If detected on setup, does not allow cycle start.
Page 34
Steam Pump Disconnected (Wiring or Connector Failure, Diode broken) Stops cycle execution. Steam Pump Failure ExC7 STEAM_PUMP_TRIAC_AL Steam Pump Alarm If detected on setup, does not allow cycle start. Steam Pump Triac Failure (Short Circuit, Diode Mode, Open Circuit) (Satellite Board Failure) STEAM_PUMP_DIODE_AL Steam Pump Diode Alarm Disables steamer activation.
Page 37
12 COMPRESSOR Volt 220/230 Power 550W Oil load 320 cm ISO VG 22 ESTER Liquid coolant R134a Total weight 14 kg Resistance of primary winding 3.6 Ohm Resistance of secondary winding 7.0 Ohm Compressor Run capacitor Motor overload cut-out 13 PTC Motor protection 1.
14 FAN COOLING COMPRESSOR Volt 220/230 Power 2600 / 3000 rpm. 15 AIR CIRCULATION FAN Volt 220 V Power 150 W 2450 rpm 16 Checking the efficiency of the heat pump To check the efficiency of the heat pump, place the sensors in the positions indicated in the figure and compare the resulting graphs with those shown below.
Page 39
DELICATE EXTRA 17 STEAMER Diagrams PUMP 400 Ω HEATER PUMP PRESSURE SWITCH HEATING ELEMENT PRESSURE TERMOFUSE SWITCH Heater Volt 220 / 230 V Power 1500 W 50 Hz Resistance at 25°C 34,93 Ω ± 5% SOI/ADL 2009-10 39/63 599 72 40-73...
Page 40
Volt 220 / 230 V Power 16 W 50 Hz Max Pressure 3,2 Bar 18 List of PNC 18.1 List of PNC - ELC for dryer EDR 1000 NEW Date of first PNC-ELC Model Brand Service Notes productions 91609272600 20050902...
Page 50
Electrolux 599385542 Date of first PNC-ELC Model Brand Service Notes productions 91609617301 20071001 EDC66150W Electrolux 599717667 91609617800 20070830 T58840 AEG Electrolux 599704489 91609617801 20071130 T58840 AEG Electrolux 599704493 91609617802 20081124 T58840 AEG Electrolux 599717663 91609617803 20090226 T58840 AEG Electrolux 599717661...
Page 51
91609618000 20071109 T57849 AEG Electrolux 599703947 91609618001 20071130 T57849 AEG Electrolux 599711356 91609618002 20081124 T57849 AEG Electrolux 599717698 91609618003 20090405 T57849 AEG Electrolux 599719529 91609618004 20090605 T57849 AEG Electrolux 599719545 91609618100 20070824 T56840R AEG Electrolux 599704620 91609618101 20071130 T56840R AEG Electrolux...
Page 52
91609621201 20071109 T55548 AEG Electrolux 599703934 Date of first PNC-ELC Model Brand Service Notes productions 91609621600 20070914 T57840 AEG Electrolux 599701883 91609621601 20071231 T57840 AEG Electrolux 599711968 91609621602 20081110 T57840 AEG Electrolux 599717834 91609621603 20090519 T57840 AEG Electrolux 599719869 91609621604...
Page 53
Model Brand Service Notes productions 91609625303 20090428 ZTE290 Zanussi 599719950 91609625304 20090626 ZTE290 Zanussi 599719966 91609625500 20071123 T56840R AEG Electrolux 599704298 91609625501 20071231 T56840R AEG Electrolux 599713407 91609625502 20081124 T56840R AEG Electrolux 599717769 91609625503 20090120 T56840R AEG Electrolux 599717770 91609625600...
Page 59
Date of first PNC-ELC Model Brand Service Notes productions 91609649600 20090814 TN75471 AEG Electrolux 599721081 91609649700 20090717 TN75481 AEG Electrolux 599720511 Husqvarna 91609650000 20090605 QW510T 599719467 Electrolux 91609650100 20090703 T57850 AEG Electrolux 599720071 91609650300 20091019 T58870 AEG Electrolux 599722002 91609650400...
Page 60
18.6 List of PNC - ELC for dryer HEAT PUMP ENV06 / ENV06 AEG Date of first PNC-ELC Model Brand Service Notes productions 91609617600 20070727 T59840 AEG Electrolux 599701449 91609618700 20080208 T59840 AEG Electrolux 599705785 91609619000 20071214 T59840 AEG Electrolux...