Bosch Climate 5000 SCI Owner's Manual

Bosch Climate 5000 SCI Owner's Manual

Middle static pressure duct type air conditioner
Hide thumbs Also See for Climate 5000 SCI:

Advertisement

Owner's Manual
Middle Static Pressure Duct Type Air Conditioner
Climate 5000 SCI
CL5000SCI
18-2 DCT/ OU- OUE
24-2 DCT/ OU- OUE
30-2 DCT/ OU- OUE
36-2 DCT/ OU- OUE
42-2 DCT/ OU- OUE
48-2 DCT/OU- OUE
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Climate 5000 SCI

  • Page 1 Owner’s Manual Middle Static Pressure Duct Type Air Conditioner Climate 5000 SCI CL5000SCI 18-2 DCT/ OU- OUE 24-2 DCT/ OU- OUE 30-2 DCT/ OU- OUE 36-2 DCT/ OU- OUE 42-2 DCT/ OU- OUE 48-2 DCT/OU- OUE IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 2: Table Of Contents

    Be aware that the refrigerants may be odourless. f Compliance with national gas regulations must be observed. f Keep ventilation openings clear of obstruction. NOTICE: The following information is required for the units with R32 refrigerant. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 3: Indoor Unit Parts And Major Functions

    To reset the louver, press the manual button, which will reset the horizontal louver settings. Refrigerant Leak Detection System (some models) In the event of a refrigerant leak, the LCD screen will display „EC“ and the LED indicator light will flash. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 4: Energy Saving Tips

    • OFF mode: When the panel is turned OFF, the unit turns off and the remote control is re-enabled. Closing curtains during heating also helps keep the heat in Fig. 2. Doors and windows should be kept closed Fig. 3. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 5: Care And Maintenance

    1. If the unit you purchased is a rear ventilated one, take off the filter in the filter dry in direct sunlight. the directions indicated by the arrows in the following diagram. 6. Re-install the filter. Fig. 5. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 6: Repairing Refrigerant Leaks

    2. Turn off the appliance and isolate the power supply. 3. Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing. 4. Remove the batteries from the remote control. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 7: Troubleshooting

    The unit's filters have become moldy and should be cleaned. The fan of the outdoor During operation, the fan speed is controlled to optimize product operation. unit does not operate Table 2. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 8: Troubleshooting Tips

    Cold air is entering through doors and windows Make sure that all doors and windows are closed during Low refrigerant due to leak or long-term use Check for leaks, re-seal if necessary and top off refrigerant Table 3. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 9: Error Codes

    High/low voltage protection Flash Compressor top overheating protection Flash Outdoor low temperature protection Flash Compressor drive error Flash Mode conflict Flash Compressor low-pressure protection Flash Outdoor IGBT sensor error Flash Indoor unit communication malfunction Table 4. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 10: European Disposal Guidelines

    The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Climate 5000 SCI – 6720887414 (2019/07)
  • Page 12 Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto: Commercial.enquiry@uk.bosch.com Contact Number 03301233004 Web address www.bosch-industrial.co.uk...