9-30
Command Diagnostic Messages
C0125 Error when reading encoder data => optional encoder
Cause
Measuring system cable defective
Measuring system defective
Encoder interface card defective
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During
the
transition
communication phase 3 (C0100) an error during the reading of the
encoder data from the data memory of the optional encoder was
detected.
Note:
Measuring systems with their own data memory are DSF/HSF
and resolvers, as well as measuring systems with EnDat
interface (Heidenhain company) and HIPERFACE interface
(Stegmann company).
Remedy
Check measuring system cable
Replace measuring system
Replace encoder interface card