03.04
1.6
Names
Effect
Names
Effect
Names
Effect
Names
Effect
Names
Effect
Names
Effect
Names
Effect
Names
Effect
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition

Cancel criteria for alarms

CANCELCLEAR
The alarm is cleared by pressing the Cancel key in any channel. It is also cleared using
the Part Program Start key.
- Clear alarm with Clear key or NC-START.
CLEARHIMSELF
Self-clearing alarm. The alarm is cleared not by an operator action but explicitly by a
"clearAlarm" programmed in the NCK source code.
- Alarm display disappears with alarm cause. No further operator action necessary.
NCSTARTCLEAR
The alarm is cleared by starting a program in the channel, in which the alarm occurred.
The alarm is also cleared by an NC Reset.
- Clear the alarm using NC START or the Reset key and continue the program.
POWERONCLEAR
The alarm is cleared by switching the control off/on.
- Switch control OFF/ON.
RESETCLEAR
The alarm is cleared by pressing the Reset key in the channel, in which the alarm
occurred.
- Clear the alarm with the Reset key. Restart part program.
BAGRESETCLEAR
The alarm is cleared by a "BAGRESETCLEAR" command or by carrying out a reset in all
channels of this mode group.
- Clear the alarm with the Reset key in all channels of this mode group. Restart part pro-
gram.
NCKRESETCLEAR
The alarm is cleared by a "NCKRESETCLEAR" command or by carrying out a reset in all
channels.
- Clear the alarm with the Reset key in all channels. Restart part program.
NOCLEAR
The clear information is only required for the internal pseudo alarm number
EXBSAL_NOMOREALARMS.
1 Alarms
1-691

Advertisement

Table of Contents
loading