14 | 1 687 001 866 / 1 682 666 309 | Assembly

2.
Assembly
2.1

NRS 1 687 001 866

2.1.1

Assembling the AMM

1. Unpack the AMM.
2. Disconnect the BEA from the mains.
3. Detach the housing cover (1) and disconnect the
ground conductor from the housing.
4. Remove the cover plate (2).
Fig. 1:
Detaching the housing
1 Housing cover
2 Cover plate
i
For BEA with production dates before FD 2004-07, it
may be necessary to drill a recess for the protruding
screw for the pump bracket.
!
Take care not to crush or trap any connecting cables
on inserting the AMM.
5. Slide the AMM into the module and attach to the
back wall with self-tapping screws.
|
1 689 978 505
2010-09-23
1
2
6. Use self-tapping screws to attach the AMM to the
base plate of the BEA.
7. Attach the connecting cables of the AMM to the
mainboard.
X5
X26
X24
X22
Fig. 2:
Mainboard connection
X5 Ribbon cable, 10-pole, measurement bench PCB
X22 Cable, 2-core, measurement bench PCB
X24 Cable, 2-core, pump
X26 Cable, 2-core, solenoid valve
8. Connect the ground conductor to the housing cover
and fit the housing cover.
2.1.2

BEA identification

Affix the following stickers to the BEA:
$
PTB sticker to right side of BEA housing cover
(Germany only, refer to information "200507_049"
in EDIS).
$
Sticker "Upgraded to BEA 350" to back wall
of BEA.
$
Sticker "Techn. data for AMM" to back wall
of AMM.