2.
Executing additional registration
Select "Current Val." in "Base Data on", adjust the
view range to capture the code 2 within the
inspection area, and execute "Training".
Additionally registers the parameters of code 2 to those
of code 1.
Module Columns Min.: 16
Module Columns Max.: 16 -> 32
Module Rows Min.: 16 -> 8
Module Rows Max.: 16
Other reading parameters are also updated.
Under this condition, the both code 1 and 2 can be
recognized. By additionally registering parameters
for codes in N ways, the condition to recognize them
can be set.
Use the same code type for Code 1 to Code N. Also, if
N is large, note that the inspection time may get longer.
Setting Example 2
(Certainly Reading Codes with Variations in
Printings)
The followings are six QR codes. The sizes of dots vary and some dots are missing. Some codes cannot
be read when the setting of Code Model Parameter is "Standard". Take the folloing procedure to read all
the codes.
Image No.0
1.
Select "Code Model Parameter".
Image No.1
Image No.2
Image No.3
Image No.4
Image No.5