Detailed description
2.4 Closed-loop control
Parameter sets during gear stage change
Interpolation parameter sets during gear stage change:
In the case of spindles, each gear stage is assigned its own parameter set.
The appropriate parameter set is activated, depending on the NC/PLC interface signal:
DB31, ... DBX16.0 - 16.2 (actual gear stage).
DB31, ... DBX16.0 - 16.2 (actual gear stage)
000
001
010
011
100
101
110
111
For more information about gear stages for spindles, see:
References:
/FB1/ Function Manual, Basic Functions; Spindles (S1).
64
1. Gearbox stage
1. Gearbox stage
2. gear stage
3. gear stage
4. gear stage
5. gear stage
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
Active parameter set
2
2
3
4
5
6
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
(Index=1)
(Index=1)
(Index=2)
(Index=3)
(Index=4)
(Index=5)