7.3 No Run Mode

The explanations in this section are based on the assumption that the module has started
normally. To change the mode from standby to run after starting the module, it is
necessary to set the local node parameters by a parameter setting request before issuing
an operation mode control request. Also, clear the scan list before setting slave device
parameters by a parameter setting request if the configuration of the slave devices is
changed.
(1) Local node parameter setting request
Parameter setting request?
Remove the cause of trouble
based on completion status.
6F8C0845
START
Is the parameter setting
request executed?
Yes
Yes
If slave device parameters have not been set yet,
END
proceed to slave device parameter setting. If they
have already been set, proceed to operation mode
control request.
Figure 7-3 Local Node Parameter Setting Request Check Items
No
Execute the local node parameter setting
request. (See 4.3.3.)
No
See how to use semaphore area in 4.2.4.
7.3 No Run Mode
7
133