EPSON Perfection1200
6. Remove 2 gold screws (CBS, 3x4) securing the shield board of the power
supply board, and remove the shield board toward inside of the body.
7. Disconnect the connector (lock type; push and release) and remove 5 gold
screws (CBS, 3x4) and power supply board from the shield board.
Figure 4-38. Power Supply Board Removal (2)
Disassembly and Assembly
Shield Board
CBS(M3x4)
Figure 4-39. Power Supply Board Removal (3)
Disassembly Procedures
CBS (M3x4)
Connector
CBS (M3x4)
Figure 4-40. Power Supply Board