INSTALLATION INSTRUCTIONS
POWER SWITCH
The Power Switch is the ON/OFF switch for the cooling system. When first turning the
unit on, there is a safety delay of 5 minutes. A red LED light beside WINE will light up to
indicate that start-up has been initiated and that that the thermostat is reading the liquid
temperature. After 5 minutes, the red LED light beside ON will light up.
CONDENSATE EVAPORATOR SWITCH
The ON position of the Condensate Evaporator Switch activates the heating element
whenever water is present in the evaporator pan. The AUTO position of the Condensate
Evaporator Switch activates the heating element at regular intervals to remove excess
water from the evaporator pan, as needed.
In most environments, the Condensate Evaporator Switch should be kept in the ON
position. If your wine vault is located in a dry climate, excess water may not accumulate
in the evaporator pan. In this case, turn the Condensate Evaporator Switch to the AUTO
setting to save electricity.