5 | Analog and Frequency Inputs
5.2.4 Configuring a multipoint adjustment
16 / 112
Measurement label
raw_name
raw_name_fi
name
name_fi
NOTICE
Working with automatically created measurement sheets is ex-
plained in chapter 'Setting up an online measurement [} 28]'.
Example: Measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
1.
Click on 'Measurement Sources' in the Toolbox.
2.
Expand the list of 'I/O Channels' by clicking on '+' in the C 70 Project Tree.
3.
Drag the 'Multipoint Adjustment' analog signal source from the Toolbox and drop it
on the desired analog input channel in C 70 Project Tree.
Data Logger C 70 Manual
Function
mV value of sensor
filtered mV value of sensor
physical value of sensor
filtered physical value
Bosch Motorsport