Bosch Rexroth AG
Assembly, Disassembly and Electrical Installation
①
Release lever
Fig. 10-3: Position of the release lever of the mounting rail holder
Removing the UPS from the mounting rail
Pull off the UPS from the mounting rail
●
Finally, remove the UPS in upwards direction
●
10.5 Electrical Wiring
10.5.1 Connecting the DC 24 V to UPS and Panel PC or Control Cabinet
PC
External power supply unit
A 24 V voltage supply supplies the UPS.
Use the Bosch Rexroth power supply unit VAP01.1H-W23-024-010-NN (see
ter 5.1 "External 24 V Power Supply Unit" on page
the external power supply unit and on the overvoltage category, please refer to
the documentation of the power supply unit.
All lines of the 24 V voltage supply have to be laid such that they are isolated
from lines carrying higher voltages.
NOTICE
Ensure that the panel PC, control cabinet PC and UPS are de-energized, before
wiring.
22/53
1
Damage to the panel PC, control cabinet PC
and UPS if connected under voltage.
7). For further information on
DOK-SUPPL*-VAU*01.1X**-IT02-EN-P
VAU 01.1
chap-