9. TROUBLESHOOTING

9.2.2 Problems that occur after the OS startup

(1) The alarm lamp is lit.
<Possible cause>
This is a hardware error notification from the RAS software or is displayed by a user
application.
<Action>
1. If the alarm lamp is lit in red, this is a hardware error notification from the RAS software.
-> The temperature is abnormal. Check the following items.
i) Make sure that sufficient clearance is provided around the equipment. (See "1.5.2
Installation".)
-> If not, provide sufficient clearance around the equipment.
ii) Make sure that the installation environment (ambient temperature) meets see "1.5.1
Environment".
-> Please make sure that the ambient temperature satisfies see "1.5.1
Environmental condition" by removal of obstacles or temperature adjustment by
air conditioning.
(2) The processing speed of the equipment is slow.
<Possible cause>
The capacity of the memory or the mSATA SSDs is not sufficient.
<Action>
1. Terminate unnecessary applications to increase available memory.
-> When you want to check the usage of the CPU and memory, follow the instructions in
"9.5 Checking the System Load by Using Performance Monitor".
2. Delete unnecessary files to increase free clearance on the mSATA SSDs.
9-6