<Diagnosis>
When the mdump command finishes, exit code 0 is returned after copying (decompressing) a
memory dump file is complete. Then some of the following messages may be displayed.
Warning: Memory dump file was not copied.
Warning: Minidump files were not copied.
(Note) If these messages are displayed, to show the cause of these messages, one of the following error
messages may be displayed depending on the way the command was executed.
When this command is terminated with an error, one of the following error messages is displayed
and exit code 1 is returned.
Error: Systemcall failed. (%s, %x)
%s: Name of the Windows API function where the error
occurred
%x: Error code from the Windows API
Error: You do not have the privilege to run this command.
Please run this command again on "Administrator: Command
Prompt".

Table 7-5 Messages of the mdump Command

Message

Table 7-6 Error Messages of the mdump Command

Message
The memory dump file could not be
copied.
Some minimum memory dump files could
not be copied.
An internal error has occurred.
You do not have administrator privileges.
Log on to the computer by using an
administrator account and run the
command again. If User Account Control
(UAC) is enabled, start the command
prompt with administrator privileges and
run the command.
7-17
7. MAINTENANCE OPERATION
Description
Description