Tips and tricks

Trace does not start n < n
If n < n
The most common reason for this is the machine data MD36060 (n<n
is not Safety machine data, is seldom used, and is therefore overlooked.
The default value is 5 mm/min or 1 rpm. Reduce the size of the data item.
Remedy:
The trace start will commence if the following prerequisite is met:
V > 2 * [MD36060]
Trace does not start (wrong direction of rotation)
If the safe actual values (NCK/drive) run contrary to the MCS actual value, then the trace
cannot start.
Remedy:
Change the direction of rotation and start the trace again.
Trace does not start (gantry and master slave)
Limit value was exceeded for one axis only as a result of mechanical occurrences or disparate
parameterization for both axes. The limit value in this regard would not necessarily have to be
exceeded for the tested axis.
Remedy:
Check the alarm messages. If the limit value was not exceeded for the axis to be tested, adapt
the parametrization.
Inserting a blank line into the template
Normal editors use the Enter key to enter a new blank line.
But if you press on the Enter key in the template editor, the next input field becomes active.
Remedy:
1. Move the cursor to the beginning of a line.
2. Press the "Ctrl + Return" key combination.
The new blank line is inserted in front of the line that is highlighted with the cursor.
SINUMERIK Operate acceptance test