Electrical Precautions

Provide a suitable power source with electrical overload protection to meet the
power requirements of the system. The power requirements per cord are - North
America: 2 phase, 208Vac, 24A max; 1 phase 110Vac, 16A max. Europe: 230Vac,
16A max.
Provide a power cord suitable for the country of installation if a power cord is not
supplied.
Provide a safe electrical ground connection to the power cord (check the
grounding of an enclosure before applying power).
Only operate the High-performance NAS Platform from nominal mains input
voltages in the range 100 - 240Vac, 60-50Hz, 7-3.5A.
Caution:Turn off all power supplies or remove all power cords before undertaking
servicing of the system.
Unplug a system component if it needs to be moved or if it is damaged.
Note: For additional data protection, it is recommended to use an external UPS to
power the High-performance NAS Platform. Also, each of the redundant power
supplies in the High-performance NAS Platform and in the storage subsystems
should be operated from a different mains power circuit in order to provide a degree
of protection from mains power supply failures. In the event that one circuit fails,
the other will continue to power the High-performance NAS Platform and the
storage subsystem.

Data Security

Each storage enclosure contains multiple removable hard disk drive (HDD)
modules. These units are fragile. Handle them with care and keep them away
from strong magnetic fields.
All supplied plug-in modules and blanking plates must be in place to complete the
internal circuitry and enable air to flow correctly around an enclosure.
Using the system for more than a few minutes with modules or blanking plates
missing can cause an enclosure to overheat, leading to power failure and data
loss. Such use may invalidate the warranty.
A loss of data can occur if a hard drive module is removed. Immediately replace
any modules that are removed. If a module is faulty, replace it with one of the
same type, of at least the same capacity and speed.
Always shut down a High-performance NAS Platform before it is moved, switched
OFF, or reset.
Maintain backup routines.