Setup Menu: IP,
Continued
SNMP Read
Description:
Parameters:
SNMP Write
Description
Add
Description:
Trap IP Address
Description:
Parameters:
Edit, Del
Description:
Parameters:
4-36
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
The SNMP Community Read and Write fields are used when
communicating with a device within an SNMP environment. These
commands allow you to set the password to read and write data to
a device to display diagnostics traps/alarms. The options are public
(default) and or a custom string.
Use the default community string called public or enter a custom
community string. To set a custom community string, enter an
alphanumeric character string up to 31-characters in length
identifying the password for the device. Note that the community
string is case-sensitive.
The SNMP Community Read and Write fields are used when
communicating with a device within an SNMP environment. These
commands allow you to set the password to read and write data to
a device to display diagnostics traps/alarms. The options are public
(default) and or a custom string.
Parameters:Use the default community string called public or a
custom community string. To set a custom community string, enter
an alphanumeric character string up to 31-characters in length
identifying the password for the device. Note: The community
string is case-sensitive.
Up to 10 entries can be assigned to the Trap Destination and
Community string fields.
This sets the destination for SNMP trap messages for events (i.e.,
fault messages).
Up to 12 digits, e.g., 155.128.100.200.
You can choose to Edit or Delete entries.
4023074 Rev B