Transponder
7.19 MDS D426
7.19
MDS D426
7.19.1
Characteristics
MDS D426
7.19.2
Ordering data
Table 7- 37
Ordering data of MDS D426
Order number
MDS D426
6GT2600-4AH00
7.19.3
Technical specifications
Product type designation
Memory size
Memory configuration
•
•
•
Storage technology
Memory organization
Protocol
228
Characteristics
Field of application
Memory
Read/write range
Standard
Serial number
Configuration memory
Application memory
Compact and rugged ISO transponder; suitable for identification of
transport units in production-related logistics; can also be deployed in
harsh conditions
FRAM 2048 bytes gross
2000°bytes net
See Chapter Field data (Page 35)
Oriented according to ISO standard 15693
MDS D426
2048 bytes
8 bytes (fixed code)
•
40 bytes
•
2000 bytes
•
FRAM
FRAM 2048 bytes / gross
2000 bytes net
Only for RF300:
When using the OPT area, 16 bytes of it must be
subtracted in 8 byte blocks
ISO 15693
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6GT2600-4AH00
SIMATIC RF200