AT^SMGO Set or query SMS overflow presentation mode or
query SMS overflow
The write command sets the overflow presentation mode.
The read command returns the overflow presentation mode and the SMS overflow status.
Syntax
Test Command
AT^SMGO=?
Response(s)
^SMGO: (list of supported<n>s)
OK
Read Command
AT^SMGO?
Response(s)
^SMGO: <n>,
<mode>
OK
ERROR
+CMS ERROR
Write Command
AT^SMGO=<n>
Response(s)
OK
ERROR
CME ERROR
Reference(s)
SIEMENS
Unsolicited Result Code
SMS buffer change:
^SMGO:
<mode>
Status of SMS buffer has changed.
Parameter Description
(num)(&W)(&V)
<n>
SMS overflow presentation mode
(&F)
[0]
1
(num)(&V)
<mode>
SMS overflow status
0
1
2
MC55_ATC_V04.00
Confidential / Released
PIN
%
Disable
Enable
Space available
SMS buffer full (The buffer for received short messages is <mem3>. See
AT+CPMS.)
Buffer full and new message waiting in SC for delivery to phone