The actual time depends on the fiber ring switch of the third party.

Issue 04 (2018-04-10)

Industrial-grade application, wide temperature range: –40° C to +60° C
High altitude: applicable at an altitude of 4000 m
Various communication modes
Bluetooth
Has a built-in Bluetooth module through which the SUN2000 APP (APP for short)
connects to the SmartLogger for parameter configuration and device maintenance.
The SmartLogger Bluetooth is named as LOG+the last eight figures of the SN of
the SmartLogger. Users can change the name.
Optical fiber ring switch
Provides two 100M Ethernet optical ports that support RSTP and STP to implement
fiber ring networking. If RSTP is used, fiber ring protection can be completed
within 10 seconds. If STP is used, fiber ring protection can be completed within 60
seconds.
PLC
Has a built-in PLC CCO through which southbound devices connect to the
SmartLogger over AC power cables.
The maximum voltage for the built-in PLC CCO of the
SmartLogger2000-10/10-B is 500 V AC. The maximum voltage for the built-in
PLC CCO of the SmartLogger2000-10-C is 800 V AC.
Ethernet electrical port
Provides two 10/100M Ethernet electrical ports that can be used as southbound
ports to connect to southbound devices or used as northbound ports to connect to an
NMS.
A southbound port connects to a downstream device for collecting data and setting parameters.
Southbound devices include the inverter, environmental monitoring instrument (EMI), electricity
meter, box-type transformer, and PID module.
A northbound port connects to an upstream NMS for uploading data.
RS485
Supports six RS485 routes and access of devices that use Modbus-RTU,
standard IEC103, and DL/T645.
RS485 supports both Modbus-Slave and Modbus-Control. If RS485 is set to
Modbus-Slave mode, the SmartLogger is in standby mode and can
interconnect with third-party data collectors and communication management
units. If RS485 is set to Modbus-Control mode, inverters that connect to the
SmartLogger conduct rapid power grid scheduling by using both PLC and
RS485 communication.
Graphical data
In addition to displaying the electricity yield and real-time monitoring information
in graphic and text format, the embedded WebUI can also display performance data
of PV plants and devices in tables or curves.
The APP displays the electricity yield and real-time monitoring information in
graphic and text format.
Centralized monitoring
The SmartLogger manages up to 200 devices in a centralized manner.
Each SmartLogger2000-10/10-B/11-B connects to a maximum of 80 inverters.