Calling Party Number Presentation For Either Isdn – Bri Or Pri - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Calling Party Number Presentation for either ISDN – BRI or PRI:
Program
Program Name/Description
Number
ETU Setup (PRTA PKG Setup) – CLIP
10-03-05
Information
Based on this setting, the system includes
Presentation Allowed (1) or Presentation
Restricted (0) in the Setup message to allow or
deny the Calling Party Number. Program
15-01-04 must also be set to 1 if this option is
enabled.
Basic Extension Data Setup – ISDN Caller ID
15-01-04
If Program 15-01-04 and Program 10-03-05 are
enabled, the system includes Caller ID in the
Setup message as Presentation Allowed. If
these options are disabled, it is Presentation
Restricted.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
20-08-13
Class of Service Options (Outgoing Call
Service) – ISDN CLIP
Determine if the ISDN calling line identity
presentation and screening indicators should
be allowed.
21-12-01
ISDN Calling Party Number Setup for Trunks
Assign Calling Party Numbers for each trunk
(maximum 16 digits per entry). When a call is
made by an extension which does not have an
Extension Calling Number assigned (Program
21-13), the system sends the calling number for
the ISDN trunk defined in 21-12. If the Calling
Party Number is assigned in both Program
21-12 and Program 21-13, the system sends
the data in Program 21-13.
21-13-01
ISDN Calling Party Number Setup for
Extensions
Assign a Calling Party Number (maximum 16
digits per entry) to each extension. The calling
number is the subscriber number of the dial-in
number. When a call is made by an extension
which does not have an Extension Calling
Number assigned (Program 21-12), the system
sends the calling number for the ISDN trunk
defined in Program 21-13. If a Calling Party
Number is assigned in both Program 21-12 and
Program 21-13, the system sends the data in
Program 21-13.
Input Data
0 = Disable
1 = Enable
0 = Disable
1 = Enable
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
Maximum of 16 characters
#
(1 ~ 0, *,
)
Maximum of 16 characters
#
(0 ~ 9, *,
)
803
Default
1
1
Extension port
101 = Class 15
All other
extension port =
Class 1
0
No Setting
No Setting

Advertisement

Table of Contents
loading

Table of Contents