Analog Outputs - Siemens 6RA7086-6KS22 Operating Instructions Manual

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
P745
Filtering time for "Main actual value" analog input
Note: Hardware filtering of approximately 1 ms is applied as standard.
(G113)
P746
Source for enabling of "Main actual value" analog input
*
Selection of binector to control enabling of the analog input ("1" state =
enabled)
(G113)
0 = binector B0000
1 = binector B0001
etc.

11.39 Analog outputs

(see also Section 8, Sheets G115 and G116)
Analog output terminals 12 / 13 (actual current display)
P749
Control word for terminal 12 (actual current display)
*
0
Output with correct sign
(positive voltage: Current in torque direction MI)
(G115)
(negative voltage: Current in torque direction MII)
1
Output of absolute value (positive voltage only)
2
Output with sign, inverted
(positive voltage: Current in torque direction MII)
(negative voltage: Current in torque direction MI)
3
Output of absolute value, inverted (negative voltage only)
Analog output terminals 14 / 15
P750
Source for output value at analog output 1
*
Selection of connector whose value is to applied to the analog output
(G115)
0 = connector K0000
1 = connector K0001
etc.
P751
Mode of signal injection at analog output 1
*
0 = Injection of signal with correct sign
1 = Injection of absolute value of signal
(G115)
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
P752
Filtering time for analog output 1
(G115)
P753
Normalization of analog output 1
P
(G115)
=
y V
[ ]
x
100
x = Normalization input (corresponds to filtering output)
y = Normalization output (corresponds to output voltage at analog output
with offset = 0)
P754
Offset for analog output 1
(G115)
Analog output terminals 16 / 17
P755
Source for output value at analog output 2
*
Selection of connector whose value is to applied to the analog output
(G115)
0 = connector K0000
1 = connector K0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
753
%
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
0 to 10000
Ind: None
[ms]
FS=0
1ms
Type: O2
All binector numbers
Ind: None
1
FS=1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
All connector
Ind: None
numbers
FS=0
1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
0 to 10000
Ind: None
[ms]
FS=0
1ms
Type: O2
-200.00 to 199.99
Ind: None
[V]
FS=10.00
0.01V
Type: I2
-10.00 to 10.00
Ind: None
[V]
FS=0.00
0.01V
Type: I2
All connector
Ind: None
numbers
FS=0
1
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
11-79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents