M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#12896
aux_PSW13dog2
Set "PSW13 area setting" 1 and 2 to specify the area where the position switch 13 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12897
aux_PSW14dog1
Set "PSW14 area setting" 1 and 2 to specify the area where the position switch 14 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12898
aux_PSW14dog2
Set "PSW14 area setting" 1 and 2 to specify the area where the position switch 14 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12899
aux_PSW15dog1
Set "PSW15 area setting" 1 and 2 to specify the area where the position switch 15 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12900
aux_PSW15dog2
Set "PSW15 area setting" 1 and 2 to specify the area where the position switch 15 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12910
aux_push
Set the command stroke of the stopper operation in the stopper positioning.
---Setting range---
0.000 to 359.999(° or mm)
#12911
aux_pusht1
Set the standby time from the stopper starting coordinate positioning to the stopper operation start in the
stopper positioning.
---Setting range---
0 to 9999(ms)
PSW13 area setting 2
PSW14 area setting 1
PSW14 area setting 2
PSW15 area setting 1
PSW15 area setting 2
Stopper amount
Stopper standby time