Connection between KX-T7600 Series DPT (except KX-T7640) and
SLT
In addition to a KX-T7600 series DPT connected in parallel, an SLT can also be connected to
KX-T7600 series DPT as follows:
To a hybrid extension port
To a hybrid extension port
To Slave DPT
Note
USB Modules must not be connected to DPTs in Digital XDP connection. If a PC is
connected to a master DPT via a USB Module, the PC cannot be used for the PC Phone,
PC Console, or CTI features. Also, if a USB module is connected to a slave DPT, the DPT
cannot work properly.
4-conductor wiring cord
Connect pins "D1" and
"D2".
4-conductor wiring cord
4-conductor wiring cord
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and "D2".
Master DPT
Slave DPT
2.6 Connection of Extensions
2-conductor wiring cord
Connect pins "T" and "R".
TO MAIN UNIT
TO TEL
/ PABX
Installation Manual
SLT
83