• Ramp/Soak
...2 CONTROL CONFIGURATION LEVEL
2.2 Ramp/Soak Profile Control
In this Section, parameters in the lower display denoted
programmed with these settings.
PrOFLE
CONtrL
SELECt
CtrL 1
CtrL 2
NONE
NONE
PrOFLE
ON
OFF
OFF
t–UNIt
MINS
HOUrS
r–h. S rc
SEG 99
NONE
run. S rc
SEG 99
NONE
HLd. S rc
SEG 99
NONE
SKIP–F
SEG 99
NONE
SKIP–b
SEG 99
NONE
6
Page Header – Profile Control.
To advance to the
Profile Program
Select Controller
Select the Controller to be programmed:
CtrL 1
Controller 1
CtrL 2
Controller 2 (if fitted)
NONE
No controller selected
Ramp/Soak Profile Enable
ON
If
is selected, Profile Control is enabled and the
. If
OFF
OPERATOR LEVEL
omitted from the
OPERATOR LEVEL
Program Time Units
Select the time units required:
MINS
Minutes
HOUrS
Hours
The time base selected applies to all segments.
Program Run/Hold Source
Select the source required to activate program run/hold. The run/hold source is level triggered i.e.
the active logic state must be maintained to select the alternative function.
If a program is activated or placed into operator hold mode
using
Program Run/Hold Source
and
have no effect.
Program Hold Source
For description of sources for this and subsequent source frames, refer to table 2.1 on page 10.
Program Run Source
Select the source required to run or restart a program. The run source is leading edge
triggered i.e. the active logic state can be removed after the
function is selected.
Program Hold Source
Select the source required to place the program running into operator hold mode. The hold
source is leading edge triggered.
The program is restarted using the
Segment Skip Forward Source
Select the source required to skip to the next segment. If the segment running is the last segment
of the program, the set point advances to the last set point value of the segment and stops the
program. The skip source is leading edge triggered.
Segment Skip Backward Source
Select the source required to skip back to the beginning of the ramp/soak segment running. The
skip source is leading edge triggered.
Continued on next page.
are Company Standard Settings. The instrument is dispatched
page press the
is selected Profile Control is disabled and the
.
, the
Program Run Source
Program Run Source.
switch.
is displayed in the
Profile States Page
Profile States Page
Run
Active
Inactive
Hold
Run
Active
Inactive
is

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents