External air cooling
Max. ambient temperature
without derating
with derating
Sound pressure level
Cooling air requirement
Max. permissible heat sink
temperature
Weight
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V (exception: 132 A and 200 A
1)
Motor Modules) and is adjusted to the parameterized rated voltage.
Rated power of a typical standard induction motor at 400 V 3 AC.
2)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
6SL3121– 1TE24-5AAx
° C
° C
dB(A)
< 65
m
/h
112
3
° C
85
kg
13,2
6.3 Motor Module with external air cooling
1TE26-0AAx
1TE28-5AAx
40
55
< 65
< 60
112
160
90
88
13,3
17,2
Motor Modules Booksize
1TE31-3AAx
1TE32-0AAx
< 73
< 73
520
520
73
80
(70%
derating)
27,1
28