Canon iPF6100 Service Manual page 682

Ipf6000 series
Hide thumbs Also See for iPF6100:
Table of Contents

Advertisement

Chapter 8
Display massage
Printhead error.
Open top cover and replace
the right printhead.
Right printhead error.
Open top cover and replace
the right printhead.
Left printhead error.
Open top cover and replace
the left printhead.
PHead needs cleaning.
Press Online to clear error.
Execute printhead cleaning.
If this message is still
displayed, replace the
printhead.
Execute printhead cleaning.
If this message is still
displayed, replace the
printhead.
Printing stopped.
Hardware error.
03800500-2F2F
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F30
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F31
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F40
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F41
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F42
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F43
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F44
Turn off printer, wait, then
turn on again.
Hardware error.
03800500-2F47
Turn off printer, wait, then
turn on again.
Clean right P Head
8-34
Code*
03800400-2803
Printhead EEPROM error
03800401-2803
Right printhead EEPROM error
03800402-280B
Left printhead EEPROM error
03800500-280C
Printhead found to have many non-discharging
nozzles during a non-discharging inspection (printing
paused)
03800500-280C
Printhead found to have many non-discharging
nozzles during a non-discharging inspection (printing
paused)
03800500-2827
Printhead found to have many non-discharging
nozzles during a non-discharging inspection (printing
stopped)
03800500-2F2F
The non-discharge of the EVEN or ODD line (640-
nozzles) is detected the 320-nozzles or more.
03800500-2F30
Detectable area failure (when adjusting the position of
non-discharging nozzle)
The gap of detection position of nozzle both ends is
big.
03800500-2F31
Non-discharge detection optical axis error
03800500-2F40
The non-discharge of all colors and chips (A/B,
EVEN/ODD) and nozzles is detected.
03800500-2F41
About all chips and nozzles of one color, the non-
discharge is detected.
03800500-2F42
About single line (A or B) and all nozzles (1280-
nozzles) of one color, the non-discharge is detected.
03800500-2F43
About single chip (A or B, EVEN or ODD) and all
nozzles (640-nozzles) of one color, the non-discharge
is detected.
03800500-2F44
The non-discharge of the EVEN or ODD line (640-
nozzles) is detected.
03800500-2F47
Head management sensor failure
The APCCHK signal of head management sensor is
out of range.
03800501-280D
The number of right printhead nozzle was over level
that can back up non-discharging nozzle. (printing
paused)
Condition detected
Action
Replace printhead.
Replace the right printhead.
Replace the left printhead.
Clean the printhead.
Identify the nozzles in a nozzle check pattern.
Replace the printhead.
Clean the printhead.
Identify the nozzles in a nozzle check pattern.
Replace the printhead.
Clean the printhead. Identify the nozzles in a nozzle
check pattern.
Replace the printhead.
Check the head management sensor and
surrounding parts.
Check that the printhead is attached correctly.
Replace the head management sensor.
Replace the printhead.
Check the ink tube unit and surrounding parts.
Check the purge unit and surrounding parts.
Check the head management sensor and
surrounding parts.
Check the flexible cable unit and surrounding parts.
Check that the printhead is attached correctly.
Replace the main controller PCB.
Replace the printhead.
Replace the carriage unit.
Check the head management sensor.
Replace the head management sensor.
Replace the printhead.
Check the ink tube unit and surrounding parts.
Check the purge unit and surrounding parts.
Check the head management sensor and
surrounding parts.
Check the flexible cable unit and surrounding parts.
Check that the printhead is attached correctly.
Replace the head management sensor.
Replace the main controller PCB.
Replace the printhead.
Replace the carriage unit.
Check the ink tube unit and surrounding parts.
Check the purge unit and surrounding parts.
Check the head management sensor and
surrounding parts.
Check the flexible cable unit and surrounding parts.
Check that the printhead is attached correctly.
Replace the main controller PCB.
Replace the printhead.
Replace the carriage unit.
Check the head management sensor and
surrounding parts.
Check the flexible cable unit and surrounding parts.
Check that the printhead is attached correctly.
Replace the main controller PCB.
Replace the printhead.
Replace the carriage unit.
Check the head management sensor and
surrounding parts.
Check the flexible cable unit and surrounding parts.
Check that the printhead is attached correctly.
Replace the main controller PCB.
Replace the printhead.
Replace the carriage unit.
Check the head management sensor and
surrounding parts.
Check that the printhead is attached correctly.
Replace the main controller PCB.
Replace the printhead.
Replace the carriage unit.
Check the head management sensor and
surrounding parts.
Replace the head management sensor.
Replace the main controller PCB.
Clean the printhead.
Change the setting of nozzle check warning.
Replace the right printhead.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipf6300Ipf6000sIpf6300sIpf6200Ipf6350

Table of Contents