Dr 23 S Cale Parameter 2 (Awi) - Siemens SIWAREX FTA Device Manual

Weighing electronics for automatic scale
Table of Contents

Advertisement

Status output condition
Net weight from TU1 to TO1
Net weight above TO1 to TO2
Net weight above TO2
Net weight from TU2 to under TU1
Net weight under TU2
Table 5-15
Tolerance information evaluation
5.16 DR 23 Scale parameter 2 (AWI)
Weighing parameters are held in DR23. These are normally typical to the scale
and do not depend heavily on the changing material properties within a limited
extent. Procedure:
o
Adjust all parameters corresponding to their purpose
o
Send DR 23 to the scale
o
If required, check parameters using tests
Name
Scale parameter 2
Text selection for
BYTE
automatic logging
Reserve 1
BYTE
Filter depth of average
WORD
value filter for dosing
Max. single set weight
REAL
Inhibition time coarse
TIME
Inhibition time fine
TIME
Inhibition time Set-Act-
TIME
comparison
Default value for analog
BYTE
output with coarse
Default value for analog
BYTE
output with fine
SIWAREX FTA
Type
Address
Default
0
DBB000
1
DBB001
0
DBB002
0
DBD004
90
Wizzard:
WB
nmax
DBD008
500
DBD012
500
DBD016
0
DBB020
60
DBB021
40
TO2
TO1
Good
0
0
1
0
1
0
1
0
0
0
0
0
0
0
0
Range of Values / Explanation
0:
No autom. logging after the
weighing procedure
1:
autom. logging with text 1
2:
autom. logging with text 2
3:
autom. logging with text 3
4:
autom. logging with text 4
Other definitions not permitted.
Reserve 1
0 ...250
0: average value filter deactivated
Other definitions not permitted.
Maximum set weight for a single
*
0: deactivated
After switching the coarse signal on, no weight
evaluation is performed for the defined amount of
time (msec)!
0: deactivated
After switching the coarse signal off, no weight
evaluation is performed for the defined amount of
time (msec)!
After the command for starting the inhibition time,
the actual weight is not monitored during the
weighing procedure for the defined amount of
time.
Analog output value if coarse signal active (in %)
Analog output value if fine signal active (in %)
Weighing Functions
TU1
TU2
Off
0
0
0
0
0
0
0
0
1
1
0
0
0
1
1
Reference
5.16.1
5.16.9
5.16.2
5.16.3
5.16.4
5.16.5
5.16.6
5.16.7
5-95