Chapter 2. SPECIFICATIONS
3) Simultaneous Voltage and Current Input Characteristics
For simultaneous voltage and current input, the input conversion switch of each channel is set to corresponding
voltage and current range.
Analog input switch has to be set upward (V1/ I).
Ex) Voltage input range: 0 to 7
- For simultaneous voltage and current input, voltage input range has to be set only to the range [-5 ~ 5 VDC].
Digital
Output
Value
- Simultaneous voltage and current input characteristics lead to digital output value as below.
Digital output
range
-192~16191
-8192~8191
Current input range: 8 to 15
Input select switch position
-5.12 V
-5 V
-20.48 mA
-20 mA
-192
0
-8192
-8000
2 - 11
Analog input range switch position
Current selection
Voltage selection
Analog Input
Analog input
0 V
5 V
0 mA
20 mA
8000
16000
0
8000
V1/ I Voltage:-5~5 VDC
Current:DC-20~20 mA
V2
8191
8000
0
-8000
-8191
5.12 V
20.48 mA
16191
8191