Configuration - Data Exchange - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Configuring
6.5 Configuring the Speed-Control Axis technology object
6.5.2.2

Configuration - Data exchange

Data exchange with the drive
In this area, you can configure the data transmission to the drive.
Message frame type (drive type PROFIdrive)
In the drop-down list, select the frame for the drive. The specification must match the setting
in the device configuration.
Reference speed (drive type PROFIdrive)
In this field, configure the reference speed of the drive in accordance with the manufacturer's
specifications. The specification of the drive's speed occurs as a percentage of the reference
speed in the range from -200% to 200%.
Reference speed (drive type analog drive connection)
The reference speed of the drive is the speed, with which the drive spins when there is an
output of 100% at the analog output. The reference speed must be configured in the drive,
and transferred into the configuration of the technology object.
The analog value that is output at 100% depends on the type of the analog output. As an
example, with an analog output with +/- 10 V, the value 10 V is output at 100%.
Analog outputs can be overloaded by about 17%. This means that an analog output can be
operated in the range from -117% to 117%, insofar as the drive permits this.
Maximum speed
In this field, specify the maximum speed of the drive.
Invert drive direction
Select the check box if the rotation direction of the drive should be inverted.