en | Operation via the browser
3.1.10

Storage, CPU and network status

When accessing the unit with a browser, the local storage,
processor and network status icons are shown in the upper
right of the window next to the Bosch logo.
When a local storage card is available, the memory card icon
changes color (green, orange or red) to indicate the local
storage activity. If you hover over this icon with the mouse the
storage activity is shown as a percentage.
If you hover over the middle icon, the CPU load is shown.
If you hover over the right-hand icon, the network load is shown.
This information can help with problem solving or when fine
tuning the unit. For example:
2015.04 | v1.592 | AM18-Q0678
if the storage activity is too high, change the recording
profile,
if the CPU load is too big, change the IVA settings,
if the network load is too big, change the encoder profile to
reduce bitrate.