Siemens SIMATIC IPC627D Operating Instructions Manual

Siemens SIMATIC IPC627D Operating Instructions Manual

Industrial pc
Hide thumbs Also See for SIMATIC IPC627D:
Table of Contents

Advertisement

SIMATIC IPC627D/827D
SIMATIC
Industrial PC
SIMATIC IPC627D/827D
Operating Instructions
09/2014
A5E32990859-AB
___________________
Preface
___________________
Overview
___________________
Safety Instructions
___________________
Installing and connecting the
device
___________________
Commissioning the device
___________________
Extended device functions
___________________
Expanding and assigning
parameters to the device
___________________
Device maintenance and
repair
___________________
Technical specifications
___________________
Technical support
___________________
Abbreviations
1
2
3
4
5
6
7
8
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC627D

  • Page 1 ___________________ SIMATIC IPC627D/827D Preface ___________________ Overview ___________________ SIMATIC Safety Instructions ___________________ Installing and connecting the device Industrial PC SIMATIC IPC627D/827D ___________________ Commissioning the device ___________________ Extended device functions Operating Instructions ___________________ Expanding and assigning parameters to the device ___________________ Device maintenance and...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions are valid for all versions of the SIMATIC IPC627D and IPC827D. Approbations You will find additional information in "Certificates and approvals (Page 101)".
  • Page 4 Preface Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC627D and SIMATIC IPC827D in this documentation. The term "Windows Embedded Standard" is used throughout to refer to "Windows Embedded Standard 7 Professional (WES 7/P)". "Windows 7" is used as an abbreviation for "Windows 7 Ultimate".
  • Page 5: Table Of Contents

    Connecting the PROFINET strain relief .................. 42 Commissioning the device ........................43 General information on commissioning .................. 43 Switching on the device ......................44 Automatic switching on of the device ..................45 Windows Action Center......................45 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 6 Integrating a new hard disk drive in the RAID system ............76 Repair and spare parts ......................78 Removing and installing hardware ..................80 7.4.1 Replacing a defective hard disk drive in the RAID system ............ 80 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 7 CE marking ........................... 102 8.2.2 ESD guideline ........................103 Dimension drawings ......................105 8.3.1 Dimension drawings of SIMATIC IPC627D ................105 8.3.2 Dimension drawings of SIMATIC IPC827D ................109 8.3.3 Dimensional drawing for the installation of expansion modules ........... 112 Technical specifications ......................
  • Page 8 Windows Embedded Standard 7 Professional ..............163 Technical support..........................165 Service and support ......................165 Troubleshooting ........................166 Notes on the use of third-party modules ................168 Abbreviations ............................169 Glossary .............................. 175 Index ..............................183 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 9: Overview

    Overview Product description The SIMATIC IPC627D and IPC827D provide a high degree of industrial functionality. ● Compact design ● Expandability (expansion card slots) ● Scalability ● Level of performance ● High degree of ruggedness 1.1.1 Applications The device are available for industrial PC systems for high-performance and space-saving applications in particular in the field of machine, plant and control cabinet engineering: ●...
  • Page 10: Features

    2560 × 1600 Core I3-4330TE: GT2 (HD Graphics 4600), • maximum resolutions up to 3840 × 2160 XEON E3-1268L v3: GT2 (HD Graphics 4600) • maximum resolutions up to 3840 × 2160 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 11 Internal: 1 × USB 3.0 high current for internal USB stick/dongle • Serial V.24 port COM2/LPT optional Monitor 1 x DVI-I (VGA monitors can be operated with a DVI/VGA adapter • acquired separately as an accessory) 1 x DisplayPort • SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 12 Software tool for local data backup and partitioning of the Creator V3.3.2 or later hard disks Expansion components Information on available expansion components is available on the Internet at the following address: IPC expansion components (http://www.automation.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories). SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 13: Design Of The Device

    Note: The BIOS setup entry "After Power Failure" has been set to "Power On". This means the device is switched on with the on/off switch. You then do not need to press the on/off button. ⑪ 4 status LEDs Status display of the operating state SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 14 ② ③ Devices with resistive single-touch screen Note If you open the sealed cover for the front USB port, the degree of protection IP65 for the front of the device is no longer guaranteed. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 15: Status Displays

    "SRAM buffer memory (optional) (Page 55)". Example programs for controlling the LEDs under Windows operating systems is available on the Internet at the following address: Technical Support (http://www.siemens.de/automation/csi_en_WW) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 16 SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes There are no "slow flashing" or "fast flashing" states. See also Industry Automation and Drive Technologies - Homepage (http://www.siemens.com/automation/service&support) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 17: Removable Drive Bay Status Displays

    Both light up RAID is not OK For information on locating the hard disk, see section "Displaying a defective hard disk of a RAID system in the RAID software". Both flash RAID is synchronizing SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 18 Overview 1.2 Design of the device SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 19: Safety Instructions

    Note that the device is classified as "Open Type" for use in the area of Industrial Control Equipment (UL508). Installation of the device in an enclosure complying with UL508 for specific permitted mounting positions (see corresponding section) is a prerequisite for approval or operation in accordance with UL508. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 20 Avoid high-frequency radiation: • Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Observe the information on electromagnetic compatibility (Page 102). SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 21 ESD Guideline (Page 103). Industrial Security Siemens offers products and solutions with Industrial Security functions that support the safe operation of equipment, solutions, machines, devices and/or networks. They are important components in a comprehensive Industrial Security concept. As a result the products and solutions from Siemens are constantly evolving.
  • Page 22: Notes On Use

    • Do not obstruct the venting slots of the device. Note Use in an industrial environment without additional protective measures This device was designed for use in a normal industrial environment according to IEC 60721-3-3. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 23: Installing And Connecting The Device

    • Keep the original packaging. • Pack the device in the original packaging for transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 24 7. Please keep the enclosed documentation in a safe place. It belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 25: Identification Data Of The Device

    CP 1616 onboard MAC Address Layer 2 (only for PROFINET devices) CP 1616 onboard MAC address PROFINET (only for PROFINET devices) Nameplate The following image shows the nameplate on the SIMATIC IPC627D as an example. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 26: Permitted Mounting Positions

    If in doubt, install the device in an enclosure that is compliant with IEC/UL/EN/DIN-EN 60950-1, sections 4.6 and 4.7.3. NOTICE Operation only in closed rooms The device is only approved for operation in closed rooms. Pay attention to the ambient and environmental conditions. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 27 Mounting positions 4 and 5 are also permitted for the Information Technology Equipment area when the device is mounted in an enclosure that fulfills the requirements stipulated by sections 4.6 and 4.7.3 of IEC/UL/EN/DIN EN 60950-1. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 28: Installing The Device

    UL508, note that the device is classified as "Open Type". The installation of the device in a housing conforming to UL508 is therefore a mandatory requirement for approval or operation in accordance with UL508. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 29: Installing The Device With Mounting Brackets

    Installing the device with mounting brackets Screw-mounting the brackets Two angle brackets are included in the product package. Secure the two brackets with six M4x6 screws, maximum penetration depth 5 mm, to the device. Use the marked threaded holes. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 30 This can result in personal injuries or material damage. Ensure that the wall is capable of bearing four times the total weight of the device (including the brackets and expansion modules). The total weight of the device is approximately 7 kg. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 31: Installing The Device With The Vertical Mounting Kit

    ② mounting plate 2. Secure the vertical mounting plate to the device using the following number of screws: – SIMATIC IPC627D: 5 x M4 screws – SIMATIC IPC827D: 7 x M4 screws Note Read the information in section Permitted mounting positions (Page 26).
  • Page 32: Installing The Device With The Vertical Mounting Kit For Pc Port Access From The Front

    Secure the vertical mounting plate to the device using five M4 screws. Two screws at the top and three at the bottom of the device. Note Read the information in section Permitted mounting positions (Page 26). SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 33: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 34: Connecting The Equipotential Bonding Circuit

    2. Connect the equipotential bonding cable with the central grounding point of the control cabinet. Make sure that the equipotential bonding cable is in contact with the central grounding point over a wide area. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 35: Connecting 100-240 Vac Power Supply

    SIMATIC PCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 36 (Off) to avoid unintentional startup of the device when you plug in the power cord. 2. Connect the appliance connector to the device. 3. Connect the power cable with the safety power outlet. 4. If necessary, install the enclosed cable grip. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 37: Connecting The 24 Vdc Power Supply

    24 VDC lines are reversed (24 VDC nominal (-20% / +20%) and connected to ground, the device will not be damaged. The device will simply fail to turn on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 38: Connecting Peripheral Equipment

    The connected or built-in I/Os, such as USB drives, should not introduce a counter EMF into the device. Reverse voltages exceeding 0.5 V to ground that are generated by connected or installed components may prevent proper operation of the device or lead to its destruction. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 39: Connecting The Device To Networks

    SIMATIC NET DVD. This software package and the documentation are not part of the product package. Additional information Additional information is available in the catalog and the online ordering system Industry Mall (https://mall.industry.siemens.com). SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 40: Profinet

    It with PG/PC: Volume 1 - Basics also describes the OPC interface as an alternative to the IO-based user programming interface. SIMATIC NET Industrial Communication with PG/PC: Volume 2 - Interfaces SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 41: Connecting Ethernet/Usb Strain Relief

    CP16xx.sys. Further information You can find the information on specific products in the Internet at the address: Product- related Information SIMATIC NET (http://www.siemens.com/simatic-net) 3.3.8 Connecting Ethernet/USB strain relief The Ethernet/USB strain relief supplied in the product package is used to prevent accidental removal of the Ethernet cable and Industrial Ethernet FastConnect connector from the device.
  • Page 42: Connecting The Profinet Strain Relief

    M3 to the de- vice housing. 2. Connect the PROFINET cables with the device and secure the PROFINET con- nector with straight cable outlet to the ② strain relief with cable ties SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 43: Commissioning The Device

    ● The protective conductor is connected. ● The connection cables are plugged in correctly. ● The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse – A monitor/display SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 44: Switching On The Device

    6. If the device is connected with a SIMATIC Industrial Flat Panel, the setup of the SIMATIC IPC Wizard is started automatically after operating system installation (see next chapter). The installation of the operating system is complete. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 45: Automatic Switching On Of The Device

    You will also receive a warning if programs attempt to modify important Windows settings. This feature is disabled in the delivery state. Configure the Security Center according to your requirements. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 46: Notes On Different Device Configurations

    "Drivers\RAID-AHCI\Intel" directory on the "Documentation and Drivers" DVD that ships with the product. Additional information on RAID1 systems can be found in the section "Managing RAID systems (Page 73)". See also Replacing a defective hard disk drive in the RAID system (Page 80) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 47: Replacing Hard Disks

    5. Lock it with the appropriate key. Note Always lock the hard disk tray in the removable drive bay to ensure reliable operation of a device with removable drive bay. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 48: Switching Off The Device

    • Protect the device and plant with a suitable uninterruptible power supply (UPS). 1. Open the function "Start > Shut down" in the Start menu. The green LED "PC ON/WD" changes to yellow. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 49: Extended Device Functions

    SIMATIC IPC DiagMonitor is available on CD (not included in the scope of delivery). The CD contains both the monitoring software and the software for the stations to be monitored. The interface specifications and a library for creating your own applications are also provided. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 50: Temperature Monitoring/Display

    Executes a hardware reset when the watchdog expires Reset off Executes no action when the watchdog expires Restart Restarts the operating system when the watchdog expires Shutdown Shuts down the operating system when the watchdog expires SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 51: Battery Monitoring

    EWF can be used to minimize write access to storage media. This is important because the write cycles are limited due to technical reasons. We therefore recommend using EWF if you work with these storage media. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 52 ● "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager" Configure the SIMATIC IPC EWF Manager as follows: ● "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings" ● Click the "SIMATIC IPC EWF Manager" icon in the system tray.
  • Page 53 "Start > Control Panel > Date and Time", remove the check mark from the "Automatically adjust clock for daylight saving changes" check box. 2. Save the change you made with and then reboot the system. ewfmgr c: commit SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 54: File Based Write Filter (Fbwf)

    This may damage the machine or plant. Make sure that you only activate one write filter for each partition. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 55: Sram Buffer Memory (Optional)

    If replacement of the battery takes longer than 30 seconds, the data saved in the CMOS RAM and in the buffered SRAM is lost. Note The buffer memory SRAM is available only with devices with PROFIBUS or PROFINET interfaces. See also Status displays (Page 15) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 56: Operation Without Monitor And Keyboard

    SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system. For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation: SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158)
  • Page 57: Trusted Platform Modul (Tpm)

    You could commit a crime by importing or exporting the device in certain countries. Note the respective import provisions for the TPM module. Activating the Trusted Platform Module The TPM can be activated under "Security" in the BIOS setup. Please follow the instructions in the BIOS setup. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 58 The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 59: Expanding And Assigning Parameters To The Device

    All technical data and approvals apply only to expansion units which are released by SIEMENS. Siemens disclaims any liability for impairment of functions caused by the use of third-party devices or components. Observe the installation instructions for the components. UL approval of the device only applies when the UL-approved components are used according to their "Conditions of...
  • Page 60: Memory Expansion

    3.2 GB. In order to avoid operating faults you may have to remove a module so that the real memory expansion on the motherboard and the reserved memory of the expansion module do not overlap. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 61 Always take appropriate precautionary measures when handling these components. Refer to the ESD directives on handling electrostatic sensitive components. Note We strongly recommend using only memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules.
  • Page 62: Expansion Cards

    ● 1 × PCI, 1 × PCIe x16 ● 1 × PCIe x4 Slot 1, 1 × PCIe x16 Slot 2 Possible configurations for IPC827D: ● 3 × PCI, 1 × PCIe x4 slot 4, 1 × PCIe x16 slot 5 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 63: Removing And Installing Expansion Cards With 627D

    Damage to the expansion card. The expansion card can break if excessive force is used. • Do not apply any pressure. • Do not apply excessive force on the slider when you push it onto the expansion card. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 64: Removing And Installing Expansion Cards With 827D

    2. Remove the slot cover from the intended slot. ③ 3. Insert the expansion card into the intended slot. 4. Install the module bracket. ④ 5. Fasten the slot cover of the expansion card. 6. Insert the slider. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 65 Note on PROFINET expansion cards For devices with CP 1616 on-board: Before you install a PROFINET expansion card, for example CP 1616, deactivate the "Onboard PROFINET" parameter in the BIOS setup "Advanced" menu, submenu "Peripheral Configuration". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 66: Drives

    2.5" hard disk: Two slots for 2.5" hard disks ② Drive bay for 2.5" hard disks One SSD drive Item Description ① SSD drive: Two slots for SSD drives ② Drive bay for SSD drive SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 67: Removing And Installing The Drive Bay Module

    Loosen the 4 screws on the holding plates. Do not remove the screws. Remove the hard disk drive including the mounting plate from the bay. Disconnect the power supply and the data cable from the drive. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 68 Removing hard disk in removable drive bay See chapter "Maintaining and repairing the device", "Removing and installing hardware", section "Removing and installing the hard disk in the removable drive bay (Page 81)". Installation Proceed in reverse order in each case. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 69: Removing And Installing An Ssd Drive

    1. Remove the drive bay module. 2. Disconnect the power supply and the data cable from the drive. ① 3. Loosen the screws of the drive. 4. Remove the drive from the bay. Installation Proceed in reverse order. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 70: Installation Options For External Drives

    DVD drive. A DVD drive The figure shows a mounted DVD drive. Two 2.5" hard disks in removable drive bay Item Description ① 2.5" hard disk ② Tray for one 2.5" hard disk SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 71: Removing And Installing A Dvd Drive

    3. Loosen the designated rivets on the left and right on the cover with a screwdriver and put the cover down with the optical drive facing down- wards. 4. Loosen the designated screws on the inside of the cover. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 72 7. Loosen the four screws that con- nect the optical drive with the drive bay and pull out the optical drive to the front from the drive bay. Installing external drive Proceed in reverse order. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 73: Device Maintenance And Repair

    Example for a RAID1 system during the boot phase of the system You can configure RAID hardware with <CTRL-I> in the boot phase. The associated description is available on the "Documentation and Drivers" DVD. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 74: Raid Software

    Execution of keyboard, mouse or touch screen commands may be briefly delayed in extreme situations. This could result in operator errors on the machine or plant. Do not operate safety-critical functions when a hard disk has failed. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 75: Displaying A Defective Hard Disk Of A Raid System In The Raid Software

    You can find information on how to detect and replace a defective hard disk in the RAID system in the section "Removing and installing hardware (Page 80)". See also Removable drive bay status displays (Page 17) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 76: Special Feature: Replacing Hard Disk In The Raid System When Switched Off

    Sequence The following figure is an example for the automatic rebuilding process. A defective hard disk is still displayed during the rebuilding process. This display disappears when the rebuilding process is completed. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 77 The new hard disk is then assigned to a SATA port and is integrated into the RAID system. A defective hard disk is still displayed during the rebuilding process. This display disappears when the rebuilding process is completed. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 78: Repair And Spare Parts

    Make sure you take precautionary measures even when you open the device, for example, when opening device doors, device covers or the housing cover. For more information, refer to the chapter "ESD Guideline (Page 103)" SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 79 UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 80: Removing And Installing Hardware

    Internal hard disk or hard disk in removable drive bay Status display RAID BIOS RAID software SATA connection of Drive the motherboard HDD0 alarm Port 0 Device port 0 SATA 0 HDD1 alarm Port 1 Device port 1 SATA 1 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 81: Removing And Installing The Hard Disk In The Removable Drive Bay

    3. Place the hard disk bay top down on a soft surface. ② 4. Loosen the screws of the drive. 5. Remove the drive from the removable drive bay. Installation Proceed in reverse order. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 82: Replacing The Backup Battery

    ● The device is disconnected from the mains and all connecting cables have been removed. Note You can also replace the battery while the device is running; do not touch anything with the device in this case. We recommend switching off the device beforehand. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 83 2. Remove the battery holder. 3. Detach the cable. 4. Remove the old battery. 5. Fasten the new battery and reinsert the battery holder. 6. Close the battery compartment. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 84: Removing And Installing The Power Supply

    (Torx T10) on the side. 3. Lift up the power supply slightly and remove the identified power supply connector from the power supply unit. 4. Lift out the power supply unit completely. Installation Proceed in reverse order. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 85: Removing And Installing The Bus Board

    2. Remove the drive bay module for hard disks. 3. Remove the power supply. ① 4. Remove the screws on the bus board. 5. Pull the bus board from the motherboard. Installation Proceed in reverse order. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 86: Removing And Installing The Power Supply Fan

    2. Loosen the four screws on the enclosure. 3. Take the power supply fan out of the enclosure. Installation Note Install only a fan of the same type. Note the correct mounting position of the fan. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 87: Removing And Installing The Device Fan

    7.4.7 Removing and installing the device fan Requirement ● The device is opened. Procedure Removal ① Remove the two screws remove the air guide pulling it up vertically. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 88 Note Install only a fan of the same type. Note the correct fan mounting position: Make sure that the blades of the fan are on the outside of the housing. Proceed in reverse order. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 89: Replacing The Processor

    If the processor type is changed, the BIOS must be updated so that the suitable microcode is loaded. Information about original spare parts for SIMATIC IPCs is available on the Internet at: – Contacts (http://www.siemens.com/automation/partner) – SIMATIC IPC after-sales information system (http://www.siemens.com/asis) Procedure ① 1. Loosen the screws The fourth screw is hidden by the air guide in the figure.
  • Page 90 If the installed processor is operated with a higher clock frequency than permitted, it can be destroyed or cause loss of data. Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 91: Installing The Software

    Note Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. other operating systems Contact the corresponding manufacturer. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 92: Installing Drivers And Software

    Specific information on using the Windows operating systems is available in the following manuals: • Windows 7, Technical Reference, MS Press No. 5913 The listed manuals are not included in the scope of delivery. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 93 You can set up partitions during the installation process and integrate storage controllers that are unknown to the operating system. To do so, select "Custom (advanced)" when prompted for the installation type in the "Install Windows" installation program. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 94 Please read the information in the section "Information for systems with RAID controller or AHCI controller". Drive options For display of additional functions that you can use to set up the data medium, (advanced) see figure "Windows installation window "Drive options (advanced)"". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 95 Integrate this driver before you partition the data medium and before you install the operating system. For more information on integrating the storage controllers, refer to the section "Information for systems with RAID controller or AHCI controller". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 96: Setting Up The Language Selection By Means Of The Multilanguage User Interface (Mui)

    For this purpose, you can either select one of the preinstalled languages or install a new language package. The following command sequences are described in English. Depending on the default setting, they can be displayed in another language. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 97 1. Choose: "Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. Select the "Keyboards and Languages" tab. 3. Click the "Install/uninstall languages" button and make the required changes. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 98: Recovery Dvd Languages

    Note Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. other operating systems Contact the corresponding provider. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 99: Installing Or Updating Application Programs And Drivers

    (images). SIMATIC IPC Image & Partition Creator supports the burning of DVD media only. You can order the tool using the Siemens online ordering system (http://www.siemens.com/automation/mall). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
  • Page 100 Device maintenance and repair 7.6 Recycling and disposal SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 101: Technical Specifications

    Certificates and approvals ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 102: Directives And Declarations

    The device meets the guidelines listed in the following sections. EC Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Certificate Box PC (http://support.automation.siemens.com/WW/view/en/10805671/134200). Electromagnetic compatibility This product meets the requirements of EC Directive 2004/108/EC "Electromagnetic Compatibility".
  • Page 103: Esd Guideline

    The material with which this person comes into contact is of particular significance. The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 104 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 105: Dimension Drawings

    Technical specifications 8.3 Dimension drawings Dimension drawings 8.3.1 Dimension drawings of SIMATIC IPC627D Dimension drawing for mounting with angle brackets SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 106 Technical specifications 8.3 Dimension drawings Dimension drawing for mounting without angle bracket SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 107 Technical specifications 8.3 Dimension drawings Dimension drawing for mounting with vertical mounting kit Note When mounting devices with optical drives, the mounting depth changes. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 108 Technical specifications 8.3 Dimension drawings Dimension drawing for installation with the vertical mounting kit for PC port access from the front SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 109: Dimension Drawings Of Simatic Ipc827D

    Technical specifications 8.3 Dimension drawings 8.3.2 Dimension drawings of SIMATIC IPC827D Dimension drawing for mounting with angle brackets SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 110 Technical specifications 8.3 Dimension drawings Dimension drawing for mounting without angle bracket SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 111 Technical specifications 8.3 Dimension drawings Dimension drawing for mounting with vertical mounting kit Note When mounting devices with optical drives, the mounting depth changes. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 112: Dimensional Drawing For The Installation Of Expansion Modules

    8.3 Dimension drawings Dimension drawing for installation with the vertical mounting kit for PC port access from the front 8.3.3 Dimensional drawing for the installation of expansion modules Short PCI or PCIe expansion card SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 113: Technical Specifications

    The device should only be connected to a 24 V DC power supply which meets the re- quirements of safe extra low voltage (SELV) according to IEC/EN/DIN EN 60950-1. A protective conductor must also be used (see section "Connecting the 24 VDC power sup- ply (Page 37)"). SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 114: Electromagnetic Compatibility

    Maximum bandwidth of PCI slots Rev. 2.0: 5 GT/s (500 Mbps) bandwidth per lane Rev. 3.0: 8 GT/s (985 Mbps) bandwidth per lane Max. accumulated power loss Total power consumption (all voltages) may not exceed 25 W. per slot SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 115 • Graphics memory 32 - 512 MB Shared Memory Resolutions/frequencies/colors DVI-I: 640 × 480 to 1920 × 1200 / 60 Hz / 24 bits DisplayPort: max. 3840 ×2160 / 130 Hz / 30 bits SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 116 For unique labeling, the Ethernet interfaces are numbered on the enclosure. The numbering by the operating system can differ. No teaming with AMT. When using AMT, the interface X1P1 must be used for connection to remote maintenance. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 117: Ambient Conditions

    Vibration: 10-58 Hz: 0.0375 mm / 58-500 Hz: 4.9 m/s Shock resistance: 25 m/s , 30 ms Restriction for hard disk drives in removable drive bay: No mechanical loads may occur at the device. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 118: Power And Energy Requirements

    The power for each individual PCI/PCIe slot must not exceed 25 W. The total power for USB and PCI/PCIe slots cannot exceed 50 W. The total power of the + 5 V and + 3.3 V voltage must not exceed 60 W. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 119: Ac Voltage Supply

    SIMATIC PCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 120 50 A for 1 ms Active power 176 W Apparent power 190 VA Output data Voltages +12 V / 12.5 A Secondary power output Max. 150 W Power Good signal of the AC power supply SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 121: Dc Power Supply

    13 A for 50 ms independent) Active power 176 W Output data Voltages +12 V / 12.5 A Secondary power output Max. 150 W Power Good signal of the DC power supply SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 122: Hardware Descriptions

    The essential components of the motherboard are the processor and the chip set, two slots for memory modules, internal and external interfaces and the Flash BIOS. ① Processor heat sink ② Slot for the bus board ③ Two memory module slots SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 123: Position Of The Interfaces On The Motherboard

    Position of the interfaces on the motherboard Interfaces The motherboard of the device features the following interfaces: ● Interfaces for the connection of external devices ● Interfaces for internal components (drives, bus boards etc.) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 124: Internal Interfaces

    Spare HDD Inter- X803 LED display Pin assignment of the device fan supply, X512 Pin no. Short description Meaning Input/Output Ground +12 V Switched voltage supply Output CPU FAN_CLK Clock signal Input PWM signal Output SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 125: Front Interfaces (Only In Combination With Ipc677D)

    Interface for I/O front USB 2.0 Internal X561 Internal USB 2.0 interface (USB channel 6) USB 3.0 Internal X560 Internal USB 3.0 interface (USB channel 3) See also Industry Automation and Drive Technologies - Homepage (http://www.siemens.com/automation/service&support) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 126: Bus Board

    Slot 2 PCI ③ Connection 12 V power supply Version 2 (IPC627D) has one PCI and one PCIe slot. ① Slot 1 PCI ② Slot 2 PCI Express x16 ③ 12V power supply connection SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 127 Version 4 (IPC827D) has three PCI and two PCIe slots. ① Slot 1 PCI ② Slot 2 PCI ③ Slot 3 PCI ④ Slot 4 PCI Express x4 (mechanical x16) ⑤ Slot 5 PCI Express x16 ⑥ 12V power supply connection SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 128: Pci Slot Pin Assignment

    AD[27] AD[26] AD[25] Ground +3.3V AD[24] C/BE[3]# IDSEL AD[23] +3.3V Ground AD[22] AD[21] AD[20] AD[19] Ground +3.3V AD[18] AD[17] AD[16] C/BE[2]# +3.3V Ground FRAME# IRDY# Ground +3.3V TRDY# DEVSEL# Ground Ground STOP# LOCK# +3.3V SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 129: Pin Assignment 12 V Power Supply Connection For Expansion Cards

    12 V voltage Output Ground Ground +5 V 5 V voltage Output max. permitted current: 1 A; with this power demand the total power demand for the PCI slots are not allowed to be exceeded. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 130: Pci Express Slot X16 Pin Assignment

    PCIE_RESET_L n.c. PCIE0_ECLK PCIEX16_TX_P(15) PCIE0_ECLK_N PCIEX16_TX_N(15) PCIEX16_RX_P(15) SDVO_CTRLCLK PCIEX16_RX_N(15) PCIEX16_TX_P(14) n.c. PCIEX16_TX_N(14) PCIEX16_RX_P(14) PCIEX16_RX_N(14) PCIEX16_TX_P(13) PCIEX16_TX_N(13) PCIEX16_RX_P(13) PCIEX16_RX_N(13) PCIEX16_TX_P(12) PCIEX16_TX_N(12) PCIEX16_RX_P(12) n.c. PCIEX16_RX_N(12) SDVO_CTRLDATA n.c. PCIEX16_TX_P(11) n.c. PCIEX16_TX_N(11) PCIEX16_RX_P(11) PCIEX16_RX_N(11) PCIEX16_TX_P(10) PCIEX16_TX_N(10) PCIEX16_RX_P(10) PCIEX16_RX_N(10) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 131 PCIEX16_TX_N(7) PCIEX16_RX_P(7) PCIEX16_RX_N(7) PCIEX16_TX_P(6) PCIEX16_TX_N(6) PCIEX16_RX_P(6) PCIEX16_RX_N(6) PCIEX16_TX_P(5) PCIEX16_TX_N(5) PCIEX16_RX_P(5) PCIEX16_RX_N(5) PCIEX16_TX_P(4) PCIEX16_TX_N(4) PCIEX16_RX_P(4) PCIEX16_RX_N(4) PCIEX16_TX_P(3) PCIEX16_TX_N(3) PCIEX16_RX_P(3) PCIEX16_RX_N(3) PCIEX16_TX_P(2) PCIEX16_TX_N(2) PCIEX16_RX_P(2) PCIEX16_RX_N(2) PCIEX16_TX_P(1) PCIEX16_TX_N(1) PCIEX16_RX_P(1) PCIEX16_RX_N(1) PCIEX16_TX_P(0) PCIEX16_TX_N(0) PCIEX16_RX_P(0) n.c. PCIEX16_RX_N(0) n.c. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 132: External Ports

    Meaning Input / output Data carrier detect Input Received data Input Transmit data Output Data terminal ready Output Ground Ready for operation Input Request to send Output Clear to send Input Incoming call Input SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 133: Displayport

    Output Ground ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (PullDown) AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 134: Dvi-I

    Analog Red Signal Output Analog green (G) Analog Green Output Signal Analog blue (B) Analog Blue Sig- Output Analog horizontal sync Analog Horizontal Output (HSYNC) Sync Signal Analog ground (analog R, Analog ground G, & return) (GND) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 135: Ethernet

    Input / output VBUS + 5 V (fused) Output Data line Input / output Data line Input / output Ground – Data line Input Data line Input Ground – Data line Output Data line Output SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 136: Profibus

    Receive data Output 7, 8 SYMT- Internal 75 Ohm terminating resistor Shield LED 1 Lights up green: link LED 2 Lights up yellow: Activity Optional product variant Auto Negotiation and auto crossover are supported SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 137: System Resources

    Motherboard resources 0030 0031 Programmable interrupt controller 0032 0033 <Not used> 0034 0035 Programmable interrupt controller 0036 0037 <Not used> 0038 0039 Programmable interrupt controller 003A 003B <Not used> 003C 003D Programmable interrupt controller SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 138 00B5 Programmable interrupt controller 00B6 00B7 <Not used> 00B8 00B9 Programmable interrupt controller 00BA 00BB <Not used> 00BC 00BD Programmable interrupt controller 00BE 00BF <Not used> 00C0 00DF DMA controller 00E0 00EF <Not used> SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 139 Motherboard resources Cascaded 2004 2007 Motherboard resources FFFF FFFF Motherboard resources Interrupt Assignments The functions are assigned different interrupts, depending on the operating system. A distinction is made between the PIC and APIC modes. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 140 Host PCI-IRQ A to H is assigned to IRQ 16 to 23 permanently in APIC mode. Host PCI-IRQ A to H will be automatically assigned IRQ 0 to 15 by BIOS in PIC mode. A specific assignment can not be enforced. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 141 1, 3 Requirement: The modules in the PCI slots each require only one interrupt Requirement: VGA and PCIexpress do not require an interrupt Requirement: VGA does not require an interrupt and Ethernet1 is disabled SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 142 FED4 4FFF 20 K Trusted Platform Module 1.2 FED9 0000 FED9 3FFF 16 K Motherboard resources FEE0 0000 FEEF FFFF Motherboard resources FF00 0000 FFFF FFFF 16 M Motherboard resources Intel 82802 firmware ® SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 143: Cp 1616 Onboard Communications Processor

    The IO base controller user program runs on the PC. This program accesses the functions of the IO base user program interface. Data traffic is routed via the communication processor to several SIMATIC S7 PROFINET IO devices, ET 200S over Industrial Ethernet. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 144 IO base user program interface. Data traffic is routed via the CP 1616 onboard communication processor to a PC as PROFINET IO controller, or to an S7-400 automation system with CP 443-1 over Industrial Ethernet. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 145: Firmware

    The firmware loader can use this information to check if the firmware is compatible to the device. Read the information provided along with the loader file, for example, in the readme file. This information is also displayed in the firmware loader when the FWL file is loaded. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 146 Note Ensure that the loader file you are using for the update is suitable for the version of firmware on your module. If you have any doubts, contact your local Siemens consultant. Note Be aware that aborting the loading process may result in an inconsistent state in your module.
  • Page 147: Further Actions In Step 7/Ncm Pc

    Do not run a BIOS update or other actions that would put a heavy load on the hardware during operation of a software CPU. Switch the software CPU to "STOP" before you run a BIOS update or perform other critical actions. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 148: Opening The Bios Selection Menu

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189185 (http://support.automation.siemens.com/WW/view/en/92189185). 8.6.2 Opening the BIOS selection menu Procedure 1.
  • Page 149 Start BIOS Setup via Setup Configuration Utility BIOS Update Update BIOS from USB memory stick MEBx Start Intel Management Engine BIOS Extension from Active Management Technology Support (AMT) Available as of Windows 8 or later SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 150: Configuration

    ⑤ ● The key assignment at the bottom shows the function keys and control keys available in BIOS Setup. You can toggle between the menus with the "←" left and "→" right cursor keys. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 151: Exit Menu

    Requirement: The parameters are saved prior to this with "Save Custom Defaults". Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 152: General Bios Setup Settings

    Visible depending on the ordered device configuration Only visible if the corresponding parameter "Internal COM #" is enabled. Only visible if "Internal LPT" is enabled. Only available if an Azalia HD audio controller is installed. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 153 USB Port 8 (USB2 P8, internal) Enabled USB Port 9 (USB2 P9, internal) Enabled USB Port 10 (USB2 P10, internal) Enabled USB Port 11 (USB2 P11, internal) Enabled Only with rack devices Only with box devices SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 154 TPM Status Depending on configura- tion TPM Operation No Operation TPM Force Clear Disabled Set Supervisor Password Set User Password Power-on Password Disabled User Access Level Full Visible depending on the ordered device configuration SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 155 Local settings Boot Type Dual Boot Type Quick Boot Enabled Quiet Boot Enabled Network Stack Disabled PXE Boot capability Disabled Add Boot Options Auto USB Boot Enabled EFI Device First Enabled Boot Delay Time SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 156: Bios Update

    BIOS update Check regularly if updates are available for download to your device. Additional information can be found on the Internet at the following address:After Sales Information system (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
  • Page 157: Alarm, Error And System Messages

    The error messages output by system BIOS are listed below. For information on error messages output by the operating system or application programs, refer to the corresponding manuals. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 158: Active Management Technology (Amt)

    KVM server is integrated in the AMT hardware. KVM enables you to reboot a remote computer and make changes to its BIOS settings. ● Remote power management SIMATIC IPC with Intel ® AMT can be switched on and off or restarted using another PC. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 159: Overview Of Amt

    The local IPC is known below as the "AMT PC". The sections contain the following information: ● AMT settings in the MEBx and in the BIOS setup ● Basic configuration of AMT ● Further useful notes SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 160: Enabling Intel® Amt / Basic Configuration

    5. Activate the option "Intel AMT Setup Prompt". 6. Exit the BIOS Setup with <F10> key (Save and Exit). Settings in the MEBx 1. Use the arrow keys to select "MEBx" and confirm with the <Enter> key. 2. Select "MEBx Login". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 161: Resetting The Intel® Amt To The Default Settings And Disabling Amt

    1. Press "F2" in the boot sequence to open the BIOS. 2. Select the "Active Management Technology Support" command in the Advanced menu, for an IPC547D/IPC547E select "AMT Configuration". 3. Set "Un-Configure ME" or "Un-Configure AMT/ME" to Enabled. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 162: Determining The Network Address

    2. Select the value "KVM" for "User Consent". To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Enable "Opt-in configurable from remote IT". SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 163: Functional Scope In Windows

    Network Diagnostics Available Pagefile Available Printing Utilities and Management Available Registry Filter Available Remote Assistance Available Remote Client Available Remote Desktop Available SIMATIC IPC DiagBase Available, V1.4 Speech Not available System Management Administrative Tools Available SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 164 Additional information on language selection is available in section "Setting up the language selection by means of the Multilanguage User Interface (MUI)". See also Setting up the language selection by means of the Multilanguage User Interface (MUI) (Page 96) SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 165: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.de/automation/csi_en_WW) ● Support request form (http://www.siemens.com/automation/support-request) ● After-sales information system for SIMATIC PC / PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 166: Troubleshooting

    2. Select BIOS setup, "Main" menu. 3. Set the time and date. Although the BIOS setting is The backup battery is dead. Replace the backup battery. OK, the time and data are still wrong. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 167 Change the boot priority of the boot device in the "Boot device not found" is boot priority in the BIOS setup or is Boot menu of the BIOS setup or permit boot device displayed excluded as a boot device in the boot priority SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 168: Notes On The Use Of Third-Party Modules

    PC. If the error no longer occurs, the Signal frequencies or signal • third-party module was the cause of the fault. Replace this levels are not adhered to module with a Siemens module or contact the module Different connector pin • supplier. assignments If the PC still crashes, contact your technical support team.
  • Page 169: Abbreviations

    Complementary Metal Oxide Complementary metal oxide semiconductors Semiconductors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer Central Processing Unit SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 170 Control character Enhanced Write Filter Frequently Asked Questions FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table FBWF File Based Write Filter Floppy disk Disk drive, 3.5" Front Side Bus Ground Chassis ground SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 171 MS-DOS Microsoft Disc Operating System MTBF Mean Time Between Failures Multilanguage User Interface Multilanguage operating system with Windows with language toggling; 5 languages: German, English, French, Spanish and Italian SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 172 Incoming call Read-Only Memory RS 485 Reconciliation Sublayer 485 Bi-directional bus system designed for up to 32 nodes Real Time Clock Real-time clock Reliable Transfer Service Request to send Receive Data Data transfer signal SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 173 Verein deutscher Elektrotechniker (Union of German Electrical Engineers) Video Graphics Array Video adapter which meets industrial standard Voltage Regulator Module Virtualization Technology Intel technology with which a virtually closed environment can be made available. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 174 Program monitoring with error detection and alarming. WLAN Wireless LAN LWireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1.024 x 768 pixels. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 175: Glossary

    Cache High-speed access buffer for interim storage (buffering) of requested data. CE marking Communauté Européene The CE mark confirms compliance of the product with corresponding EC Directives, for example, with the EMC Directive. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 176 The data are stored in a configuration file and enable the operating system to load the correct device drivers and configure the correct device parameters. . If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. . SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 177 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 178 Intel Active Management Technology This technology permits the diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 179 Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 180 Restricted Access Location: Installation of the device in a production facility with restricted access, for example, a locked control cabinet. Recovery CD Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 181 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 182 Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 183: Index

    Certifications and approvals, 28 Dimensions, 113, 113 Climatic conditions, 117 Directive Clock frequency, 90 ESD Directive, 103 COA label, 26 DisplayPort COM1 port, 132 Interface, 133 Components sensitive to electrostatic charge, 103 Documentation and Drivers CD/DVD, 91 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 184 EC Declaration of Conformity, 102 Mech. Ambient conditions, 117 Memory configuration, 62 Memory expansion, 60 Hard disk Memory media Removing, 67 Drives, 113 Hard disk drive, 115 Memory modules, 114 Installing, 60, 61 Removing, 62 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 185 Fan, 87 RJ45 Ethernet, 135 Hard disk, 67 USB 3.0, 135 Memory modules, 62 Power consumption, 113 Power supply fan, 86 Power factor correction, 119 Power supply unit, 84 Power Good signal, 120 Processor, 89 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...
  • Page 186 System resources, 137 I/O address allocation, 137 Temperature, 117 Temperature monitoring, 50 Third-party modules, 168 Troubleshooting/FAQs, 166 UL approval, 101 Updates Application programs and drives, 99 Operating system, 91, 91, 98, 98 USB 3.0 Port, 135 SIMATIC IPC627D/827D Operating Instructions, 09/2014, A5E32990859-AB...

This manual is also suitable for:

Simatic ipc827d

Table of Contents