B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 23 of 41)
ADDR
REGISTER NAME
7004
Phase UV1 Delay
7005
Phase UV1 Minimum Voltage
7006
Phase UV1 Block
7007
Phase UV1 Target
7008
Phase UV1 Events
B
7009
Phase UV Measurement Mode
700A
Reserved (6 items)
7013
...Repeated for module number 2
Phase Overvoltage (Read/Write Grouped Setting)
7040
Phase OV1 Function
7041
Phase OV1 Source
7042
Phase OV1 Pickup
7043
Phase OV1 Delay
7044
Phase OV1 Reset Delay
7045
Phase OV1 Block
7046
Phase OV1 Target
7047
Phase OV1 Events
7048
Reserved (8 items)
Distance (Read/Write Grouped Setting)
7060
Distance Signal Source
7061
Memory Duration
7062
Force Self-Polar
Line Pickup (Read/Write Grouped Setting)
71F0
Line Pickup Function
71F1
Line Pickup Signal Source
71F2
Line Pickup Phase IOC Pickup
71F3
Line Pickup UV Pickup
71F4
Line End Open Pickup Delay
71F5
Line End Open Reset Delay
71F6
Line Pickup OV Pickup Delay
71F7
Autoreclose Coordination Pickup Delay
71F8
Autoreclose Coordination Reset Delay
71F9
Autoreclose Coordination Bypass
71FA
Line Pickup Block
71FB
Line Pickup Target
71FC
Line Pickup Events
71FD
Terminal Open
71FE
AR Accelerate
Breaker Failure (Read/Write Grouped Setting) (2 modules)
7200
Breaker Failure 1 Function
7201
Breaker Failure 1 Mode
7208
Breaker Failure 1 Source
7209
Breaker Failure 1 Amp Supervision
720A
Breaker Failure 1 Use Seal-In
720B
Breaker Failure 1 Three Pole Initiate
720C
Breaker Failure 1 Block
720D
Breaker Failure 1 Phase Amp Supv Pickup
720E
Breaker Failure 1 Neutral Amp Supv Pickup
720F
Breaker Failure 1 Use Timer 1
7210
Breaker Failure 1 Timer 1 Pickup
7211
Breaker Failure 1 Use Timer 2
7212
Breaker Failure 1 Timer 2 Pickup
7213
Breaker Failure 1 Use Timer 3
7214
Breaker Failure 1 Timer 3 Pickup
B-30
RANGE
0 to 600
0 to 3
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 5
5 to 25
0 to 65535
0 to 1
0 to 5
0 to 30
0 to 3
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
L90 Line Differential Relay
APPENDIX B
UNITS
STEP
FORMAT
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
0 (Phase to Ground)
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
cycles
1
F001
---
1
F300
---
1
F102
---
1
F167
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
1
F300
---
1
F300
---
1
F102
---
1
F157
---
1
F167
---
1
F126
---
1
F126
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
DEFAULT
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (SRC 1)
10
0
0 (Disabled)
0 (SRC 1)
1000
700
150
90
40
45
5
1 (Enabled)
0
0 (Self-reset)
0 (Disabled)
0
0
0 (Disabled)
0 (3-Pole)
0 (SRC 1)
1 (Yes)
1 (Yes)
0
0
1050
1050
1 (Yes)
0
1 (Yes)
0
1 (Yes)
0