ANI4 installation instructions
Follow the steps below to install ANI4 in the HiPath 3550 or HiPath 3350 system.
Caution
7
Remove the trunk slip-on connectors from the TMGL4 board before starting to work
on the system.
Be sure to reinstall the ANI4 and TMGL4 boards in their slots before reconnecting
the trunks.
1.
Disconnect the trunks from theTMGL4 board (Figure 3-149: Figure 1).
2.
Unplug the system from the power supply.
3.
Install the ANI4 board in the system.
4.
Connect the OPAL adapter cable to the ANI4 board.
5.
Use the ribbon cable supplied with the board to connect ANI4 and TMGL4, making sure
that the colored markings (pin 1) at both ends of the cable are facing upwards(Figure 3-
149: Figure 2).
6.
Connect the trunk slip-on connectors to the ANI4 (Figure 3-149: Figure 3).
7.
Restart the system by reconnecting the power plug.
Fig. 1
Figure 3-149
ANI4 (for selected countries only) - Installation Steps
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Fig. 2
Pin 1
Pin 1