Notice
1. Detach and attach the upper case.
Follow the procedure below to detach and attach the upper case.
When disassembling
a. Remove the Lamp door.
The lamp door must be removed before the upper case when disassembling the machine. If the upper
case is detached with the lamp door installed, the MAIN board might be damaged.
Loosen this screw
b. Remove 9 screws on the bottom and 1 screw on the side to detach the upper case.
Put the projector on soft sheet when you tighten / remove the screws on the bottom.
CP-A100 / ED-A100 / ED-A110 (A1DN)
CAUTION
Lamp door
CAUTION
This screws
56
9 screws