Gb Lan Pass Through Module - Hitachi Compute Blade 2000 User Manual

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

1 Gb LAN pass-through module
Notes on Use
Line0 to 15 of the LAN pass-through module, which is based on Auto-MDI/MDIX, can be
connected with either a cross cable or a straight cable. The line rate of Line0 to 15 is
1000BASE-T only.
When you use a cable with a covered plug, the cover may interfere with cable connection. If
so, remove the cover from the plug to connect it.
If the cable is difficult to remove, you can use a cable removal tool (CBL) for removing LAN
cables as described in the following steps.
1. Insert the plug firmly to unlock the plug.
2. Place the tip of the CBL removal tool, which is attached to the LAN pass-through
module, on the latch of the plug, and press the latch.
3. While pressing the latch, pull out the cable.
Keep the CBL removal tool for removing a LAN cable attached to the LAN pass-through
module.
850

Advertisement

Table of Contents
loading

Table of Contents